A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Sirolimus-eluting stent in chronic total occlusion: the SICTO study. | LitMetric

AI Article Synopsis

  • Coronary stenting with CYPHER sirolimus-eluting stents has been shown to effectively reduce the rates of restenosis and reocclusion after balloon angioplasty for chronic total occlusions (CTOs).
  • In a study involving 25 patients, the angiographic outcomes at 6 months indicated no significant change in lumen diameter and a 0% in-stent restenosis rate.
  • Long-term follow-up demonstrated low rates of target lesion and target vessel revascularization, confirming the safety and efficacy of the CYPHER stent compared to traditional bare metal stents.

Article Abstract

Coronary stenting can significantly reduce the restenosis and reocclusion rates after successful balloon angioplasty for chronic total occlusions (CTO). Nevertheless, recanalization of CTO remains among the worst predictors for in-stent restenosis and reocclusion. This multicenter, nonrandomized study assessed the safety and effectiveness of the CYPHER sirolimus-eluting stent in reducing angiographic in-stent late loss in totally occluded native coronary arteries. A total of 25 eligible patients were treated with the CYPHER sirolimus-eluting stent. Baseline clinical and angiographic data were collected and 6-month follow-up angiography and intravascular ultrasound (IVUS) were performed. Clinical follow-up was required at 30 days, 6, 12, 18, and 24 months. Study stent implantation was successful in all patients, with a mean stent length of 28.4 +/- 11 mm. Six-month angiographic outcomes showed that mean lumen diameter stenosis did not change (2.22 +/- 0.56 mm postprocedure; 2.26 +/- 0.60 mm at 6 months follow-up; P = NS). Similarly, mean percent diameter stenosis did not change significantly (15.7 +/- 8.6% postprocedure, 19.3 +/- 11% at follow-up; P = NS). The absolute late lumen loss was -0.03 +/- 0.28 mm with a 6-month in-stent restenosis rate of 0%. IVUS follow-up revealed in-stent obstruction volume of only 4.9 +/- 6.8%. Long-term clinical follow-up showed target lesion revascularization at 12 months was only 4%, with target vessel revascularization of only 12%. The CYPHER sirolimus-eluting stent was safe and effective in the treatment of CTO compared to historical data with bare metal stents.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8183.2006.00151.xDOI Listing

Publication Analysis

Top Keywords

sirolimus-eluting stent
16
cypher sirolimus-eluting
12
chronic total
8
restenosis reocclusion
8
in-stent restenosis
8
clinical follow-up
8
diameter stenosis
8
stenosis change
8
+/-
7
follow-up
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!