Determination of bisphenol A in milk by solid phase extraction and liquid chromatography-mass spectrometry.

J Chromatogr A

Laboratory of Analytical Chemistry, Department of Chemistry, University of Athens, Panepistimioupolis Zografou, Athens, Greece.

Published: October 2006

A simple and reliable analytical method based on solid phase extraction (SPE) and liquid chromatography coupled with electrospray ionization mass spectrometry was developed for the determination of bisphenol A (BPA) in milk. The effects of the experimental parameters of the LC-ESI-MS system (mobile phase and additives, flow rate, temperature of the ionization source, cone voltage and capillary potential) on the obtained signal were assessed and the parameters were optimized to provide maximum sensitivity and detectability. In addition, the performance of three commercial SPE sorbents (C18, PS-DVB and hydroxylated PS-DVB) was evaluated using spiked water and milk, diluted with a mixture of water-methanol (8:1). By using C18 cartridges and BPA-d(16) as internal standard, the mean relative recoveries at three fortification levels ranged between 97 and 104% and the corresponding inter-day precision (RSD%) was below 6% for 50 and 500 ng/g and below 20% for 5 ng/g fortification levels. It is shown that the ion suppression during ESI, the losses from the sample preparation procedure and the inter-day instability of LC-ESI-MS were overcome by the use of the deuterated internal standard. The concentration of BPA found in commercial canned milk samples ranged from <1.7 to 15.2 ng/g.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2006.06.103DOI Listing

Publication Analysis

Top Keywords

determination bisphenol
8
solid phase
8
phase extraction
8
internal standard
8
fortification levels
8
milk
4
bisphenol milk
4
milk solid
4
extraction liquid
4
liquid chromatography-mass
4

Similar Publications

The purpose of the current study was to investigate the potential ameliorating murine reproductive effects of herbal tea extracts against bisphenol A-induced (BPA) cytotoxicity. A comparative study was applied among red, green and blue teas in mice groups. Samples were coded as RTE, GTE and BTE groups, respectively.

View Article and Find Full Text PDF

The use of nanozymes for electrochemical detection in the food industry is an intriguing area of research. In this study, we synthesized a laccase mimicking the MnO@CeO nanozyme using a simple hydrothermal method, which was characterized by modern analytical methods, such as transmission electron microscope (TEM), X-ray diffraction (XRD), and energy dispersive X-ray spectroscopy (EDX), etc. We found that the addition of MnO significantly increased the laccase-like activity by 300% compared to CeO nanorods.

View Article and Find Full Text PDF

Natural Eutectic Solvent-Based Temperature-Controlled Liquid-Liquid Microextraction and Nano-Liquid Chromatography for the Analysis of Herbal Aqueous Samples.

Foods

December 2024

Departamento de Química, Área de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL), Avenida Astrofísico Francisco Sánchez s/n, 38206 San Cristóbal de La Laguna, Tenerife, Spain.

In this work, two novel (-)-menthol-based hydrophobic natural eutectic solvents with vanillin and cinnamic acid were prepared and applied as extraction solvents. In this regard, 12 endocrine disruptors, including phenol, 2,4-dimethylphenol, 2,3,6-trimethylphenol, 4--butylphenol, 4--butylphenol, 4--amylphenol, 4--hexylphenol, 4--octylphenol, 4--heptylphenol, 4--octylphenol, and 4--nonylphenol and bisphenol A, were studied in a green tea drink. A temperature-controlled liquid-liquid microextraction was used as the extraction method, and nano-liquid chromatography-ultraviolet detection was used as the separation and determination system.

View Article and Find Full Text PDF

Bisphenols may negatively impact human health. In this study, we propose the use of HPLC-FLD for the simultaneous determination of bisphenols in pericardial fluid samples collected from patients with coronary artery disease undergoing coronary artery bypass surgery. For sample preparation, a fast, simple, and "green" DLLME method was used, achieving mean recovery values in the range of 62%-98% with relative standard deviations between 2% and 6% for all analytes.

View Article and Find Full Text PDF

Safer chemical alternatives to bisphenol (BP) have been a major pursuit of modern green chemistry and toxicology. Using a chemical similarity-based approach, it is difficult to identify minor structural differences that contribute to the significant changes of toxicity. Here, we used omics and computational toxicology to identify chemical features associated with BP analogue-induced embryonic toxicity, offering valuable insights to inform the design of safer chemical alternatives.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!