A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Contrast sensitivity and disability glare in patients with dry eye. | LitMetric

Purpose: To evaluate contrast sensitivity and disability glare in patients with dry eye using the Contrast Glaretester 1000.

Methods: Contrast sensitivity and disability glare were determined in 33 eyes of 33 patients with dry eye and 30 eyes of 30 healthy control subjects for six target sizes with a visual angle of 6.3-0.7 degrees using the Contrast Glaretester 1000, whose working mechanism is similar to that of the conventional perimetry instrument.

Results: Contrast sensitivity was significantly worse in dry eye group when viewing all target sizes (reduction of 0.10-0.25 log contrast units, p < 0.01) except at 6.3 degrees. In the presence of glare, differences in log contrast sensitivity between the groups (0.10-0.25 units) were significant (p < 0.01) for all target sizes, with the dry eye group showing worse results. The reduction in contrast sensitivity induced by glare (disability glare) was significantly worse in the dry eye group versus the control group but only for the 2.5-degree size target, where 0.14 log contrast units were lost.

Conclusions: Contrast sensitivity with and without glare was significantly reduced in patients with dry eye compared with control subjects, but the number of log contrast units lost with glare (disability glare) was similar in the two groups, except for the 2.5-degree size target.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0420.2006.00671.xDOI Listing

Publication Analysis

Top Keywords

contrast sensitivity
28
dry eye
28
disability glare
20
patients dry
16
log contrast
16
contrast
12
sensitivity disability
12
target sizes
12
eye group
12
contrast units
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!