A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A biodegradable button to augment suture attachment in rotator cuff repair. | LitMetric

Recent experimental studies suggest that the use of suture anchors for rotator cuff tear (RCT) repair transfers the "weak link" to the suture-tendon interface where failure occurs as the sutures cut through the tendon. The purpose of this study was to evaluate the effect of using a suture augmentation button on the fixation strength of rotator cuff tendon repair. A 1.5 cm by 2 cm defect was created in the supraspinatus tendon of seven cadaveric shoulder pairs and two suture anchors inserted in each humerus for suture attachment. For one of each pair, the defect was repaired with sutures placed in a horizontal mattress configuration. The other side was repaired with the sutures being passed through low profile, bioabsorbable buttons placed on the bursal tendon surface prior to knot tying. The supraspinatus tendon was cyclically loaded at a physiologic rate and load (33 mm/sec and 180 N, respectively). The number of loading cycles was recorded when the specimens developed 0.75 cm and 1.5 cm gaps at the repair site. The specimens were then tested to failure. Specimens in the unaugmented group developed 0.75 cm and 1.5 cm gaps at an average of 135 cycles and 362 cycles, respectively. The button augmented group developed these gaps at average of 420 cycles and 708 cycles, respectively. These differences were statistically significant (p < 0.05). The gaps progressively increased in all specimens, which eventually failed by suture cutting through tendon in all specimens. This study demonstrates that in vitro, suture augmentation with a low profile, bioabsorbable button provides significantly enhanced fixation when using suture anchors to repair torn rotator cuff tendon. This device may be a useful adjunct to current methods of rotator cuff repair.

Download full-text PDF

Source

Publication Analysis

Top Keywords

rotator cuff
20
suture anchors
12
suture
8
suture attachment
8
cuff repair
8
suture augmentation
8
cuff tendon
8
supraspinatus tendon
8
repaired sutures
8
low profile
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!