Purpose: To evaluate the treatment parameters necessary for achieving ciliary body photodynamic damage, enough to significantly reduce IOP, using verteporfin and a diode laser.
Design: Animal study.
Methods: The right eye ciliary body of 30 pigmented rabbits was irradiated using verteporfin (Visudyne) and a diode laser. Photosensitizer dose ranged from 0.375 to 2 mg/kg. Three adjacent laser spots were applied 0.5 mm behind limbus at 12 o'clock position using a contact transscleral technique. The laser power was ranging from 10 to 70 mW and the duration of irradiation from 1 to 5 min per spot. The left eyes of the rabbits were used as controls. Animals were sacrificed 24 hours after the procedure and their eyes were evaluated by means of light and electron microscopy. A step-by-step approach was adopted with adjustment of experimental parameters according to histological findings. The end point was to identify the irradiation parameters necessary for induction of photodynamic damage while minimizing thermal damage. Subsequently, 10 more animals were used in order to verify the effectiveness of these irradiation parameters in reducing the intraocular pressure.
Results: The therapy parameters that led to photodynamic effect avoiding thermal damage were laser power of 25 mW, irradiation time of 3 min per spot, and verteporfin dose of 1 mg/kg. Transscleral ciliary body irradiation using these parameters resulted in vascular thrombosis of ciliary vessels and in substantial edema, resulting in separation of the two ciliary epithelium layers. These parameters were applied to 4 rabbits, resulting in a mean IOP reduction of 1.8 mmHg +/- 1.2 that lasted for 4 days. An increase of the laser power to 35 mW tested in 6 additional animals, resulted in mean IOP reduction of 2.2 mmHg +/- 1.2, lasting 6 days; some minimal thermal damage was seen with the later settings.
Conclusion: The combination of verteporfin and 690 nm diode laser is effective for the induction of ciliary body photodynamic damage, which results in significant but temporary IOP reduction, after transscleral PDT in pigmented rabbits. With appropriate parameter selection, intraocular pressure reduction can be achieved while thermal damage is kept to a minimum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02713680600788189 | DOI Listing |
A 3-year-old girl treated with intravenous chemotherapy for bilateral retinoblastoma (RB) and a standard technique of intravitreal topotecan for vitreous seeds in the left eye developed a conjunctival nodule at the injection site. Ultrasound biomicroscopy showed normal underlying sclera and ciliary body. Fundus examination of the left eye showed partly calcified vitreous seeds.
View Article and Find Full Text PDFNature
January 2025
Department of Biochemistry and Molecular Biophysics, Washington University in St. Louis, School of Medicine, St. Louis, MO, USA.
Reproduction, development and homeostasis depend on motile cilia, whose rhythmic beating is powered by a microtubule-based molecular machine called the axoneme. Although an atomic model of the axoneme is available for the alga Chlamydomonas reinhardtii, structures of mammalian axonemes are incomplete. Furthermore, we do not fully understand how molecular structures of axonemes vary across motile-ciliated cell types in the body.
View Article and Find Full Text PDFBackground: The ciliary muscle is known to play a part in presbyopia, but the mechanism has not received a comprehensive review, which this study aims to achieve. We examined relevant articles published from 1975 through 2022 that explored various properties of the muscle and related tissues in humans and rhesus monkeys. These properties include geometry, elasticity, rigidity, and composition, and were studied using a range of imaging technologies, computer models, and surgical methods.
View Article and Find Full Text PDFSci Rep
December 2024
Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.
View Article and Find Full Text PDFAdv Sci (Weinh)
December 2024
Department of Ultrasound in Medicine, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, No. 600, Yishan Road, Shanghai, 200233, P. R. China.
Rapid thrombolysis is very important to reduce complications caused by vascular blockage. A promising approach for improving thrombolysis efficiency is utilizing the permanent magnetically actuated locomotion of nanorobots. However, the thrombolytic drug transportation efficiency is challenged by in-plane rotating locomotion and the insufficient drug penetration limits further improvement of thrombolysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!