Objectives: The aim of this study was to validate noncontact mapping (NCM) in the left atrium (LA) during sinus rhythm and atrial fibrillation (AF).
Background: Understanding the mechanisms of AF is crucial to the development of novel and effective treatments. Noncontact mapping records global electrical activation simultaneously and therefore has the potential to elucidate these mechanisms.
Methods: Patients underwent catheter ablation of permanent AF guided by NCM. Virtual and contact unipolar electrograms were recorded simultaneously during sinus rhythm and AF from sites spanning the LA and their morphology, amplitude, and timing were compared. The impact of distance from the array to the endocardial surface and electrogram amplitude were analyzed.
Results: A total of 22 patients age 52 +/- 9 (mean +/- SD) years were studied. During sinus rhythm, the median (range) morphology correlation and timing difference between contact and virtual atrial electrograms were 0.81 (0.27 to 0.98) and 4.2 (0 to 18.3) ms, respectively. These results were significantly worse than the corresponding far field individual ventricular electrograms; 0.91 (0.53 to 1.0) and 1.7 (0 to 18.3) ms (p < 0.001). For endocardial sites >40 mm from the array, the correlation was significantly worse than sites <40 mm: 0.73 (0.48 to 0.95) versus 0.87 (0.27 to 0.98) (p < 0.001). The correlation during AF was 0.72 (0.24 to 0.98), which deteriorated with increasing distance from the array. In the presence of adenosine induced atrioventricular block the correlation deteriorated 0.67 +/- 0.16 versus 0.79 +/- 0.11 (p < 0.001).
Conclusions: Noncontact mapping can be performed in human LA; however, the accuracy of reconstructed electrograms is poor >40 mm from the center of the array, particularly during AF. Care must be taken interpreting isopotential maps if the entire endocardial surface of the LA is not close to the array.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2006.04.069 | DOI Listing |
Int J Cardiol Heart Vasc
February 2025
Dept. of Cardiology, Erasmus University Medical Center, Rotterdam, the Netherlands.
Background: Areas of conduction disorders play an important role in both initiation and perpetuation of AF and can be recognized by specific changes in unipolar potential morphology. For example, EGM fractionation may be caused by asynchronous activation of adjacent cardiomyocytes because of structural barriers such as fibrotic strands. However, it is unknown whether there are sex differences in unipolar potential morphology.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Department of Cardiovascular Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.
Atrial fibrillation (AF) is the most common tachyarrhythmia and seriously affects human health. Key targets of AF bioinformatics analysis can help to better understand the pathogenesis of AF and develop therapeutic targets. The left atrial appendage tissue of 20 patients with AF and 10 patients with sinus rhythm were collected for sequencing, and the expression data of the atrial tissue were obtained.
View Article and Find Full Text PDFBMC Cardiovasc Disord
January 2025
The First Affiliated Hospital of Dalian Medical University, 222 Zhongshan Rd Dalian, Liaoning, Liaoning, 116011, China.
Purpose: Catheter ablation (CA) for atrial fibrillation (AF) in heart failure patients with preserved ejection fraction (HFPEF) has shown promising results in reducing mortality and improving heart function. However, previous studies have been limited by a lack of control groups and significant heterogeneity in their methodologies.
Hypothesis: CA for AF in HFPEF patients may not increase the complications and had similarly the rate of freedom from AF vs.
Background: In developing countries, rheumatic mitral valve stenosis (MS) is still a problem and its progression leads to left atrial (LA) damage. Due to the complexity of the LA geometry, currently used techniques like antero-posterior dimension (LAD) and 2D echo derived LA volume (LAV) have several limitations that are corrected by 3D derived LA volumes in addition to functional evaluation.
Purpose: To assess the LA functions using 2D speckle tracking echocardiography and 3D transthoracic echocardiography in patients with clinically significant MS in comparison to normal healthy subjects.
JACC Clin Electrophysiol
January 2025
Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, California, USA; Metro Health Medical Center, Case Western Reserve University School of Medicine, Cleveland, Ohio, USA; Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy. Electronic address:
Background: Earlier studies have documented the risk for sinoatrial node injury and phrenic nerve paralysis as complications following radiofrequency catheter ablation for electrical isolation of the superior vena cava (SVCI).
Objectives: The aim of this study was to assess the safety and feasibility of SVCI in patients with atrial fibrillation undergoing pulsed field ablation (PFA) METHODS: Six hundred sixteen consecutive patients undergoing PFA for pulmonary vein isolation plus SVCI were included in this multicenter analysis. Superior vena cava (SVC) ablation was performed under the continuous guidance of intracardiac echocardiography.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!