A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[In vitro cytotoxicity of different self-etching dental adhesive systems]. | LitMetric

[In vitro cytotoxicity of different self-etching dental adhesive systems].

Schweiz Monatsschr Zahnmed

Abteilung Zahnerhaltung, Präventive Zahnheilkunde und Parodontologie, Zentrum für Zahn-, Mund- und Kieferheilkunde, Universität Göttingen.

Published: August 2006

The study evaluated the cytotoxicity of five self-etching dentin adhesive systems applied on dentin specimens of different thicknesses. The test materials (A: Adper Prompt-L-Pop, B: Xeno II, C: Clearfil SE Bond, D: One up Bond F, E: Resulcin Aqua Prime & Monobond) and a positive control (35% H202) were applied on 1.0, 1.5 and 2.5 mm thick bovine dentin specimens (each subgroup n = 5) in a dentin barrier test device. The experiments were performed with perfusion (2 ml/h) of the pulpal part of the chamber. The eluates were obtained before (baseline) and 15, 30, 45, 60 and 120 min after application of the adhesives and pipetted onto L-929 fibroblasts. Cytotoxicity of the materials was determined in relation to the baseline value using the MTT assay and statistical analysis was performed by ANOVA. After 15 min perfusion, test materials B-E applied on 1.0 mm and B and E applied on 1.5 mm dentin specimens exhibited cytotoxic potential. However, after 30 min perfusion none of the adhesives showed any toxicity. Cytotoxicity decreased with increasing thickness of the dentin slices and was lower for Adper Prompt-L-Pop compared to adhesives B-E. Self-etching adhesive systems might exhibit cytotoxic potential when applied on dentin of less than 1.5 mm thickness. However, cytotoxicity of the materials decreased with increasing dentin thickness and increasing duration of perfusion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

applied dentin
12
dentin specimens
12
cytotoxicity self-etching
8
dentin
8
adhesive systems
8
test materials
8
adper prompt-l-pop
8
cytotoxicity materials
8
min perfusion
8
cytotoxic potential
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!