A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Achieving durable glucose control in the intensive care unit without hypoglycaemia: a new practical IV insulin protocol. | LitMetric

Background: Hyperglycaemia occurs in a substantial portion of critically ill patients in our intensive care units. Near normalization of elevated blood glucose levels with IV insulin may improve outcome. However, currently published IV insulin protocol are not ideal; most are relatively complex and often result in hypoglycaemia. We designed a protocol that would be practical to use while incorporating the necessary complexities required to achieve good glucose control, coupled with a low incidence hypoglycaemia.

Methods: The essential part of the protocol is a matrix specifying the amount by which an insulin flow rate is to be changed. The intersection of the current and the previous blood glucose values on the matrix locates the appropriate cell containing the required change in insulin flow rate. No additional calculations or tables are required.

Results: The initial glucose level obtained by blood glucose meter (BGM) averaged 253.5 +/- 95.6 mg/dL and fell below 140 within 9.3 h on the protocol. The average BGM on the protocol was 133.5 +/- 43.9 mg/dL. Only 0.09% of all glucose values were <40 mg/dL and insulin had to be held only 2.2% of the time on the protocol. Physician input was not required and nursing accuracy in applying the protocol was greater than 94%. This protocol has been adopted as the default IV insulin protocol for the NorthShore-LIJ Health System and several other medical centers.

Conclusion: A practical IV insulin protocol that has been extensively tested is presented. The protocol has been implemented at multiple institutions indicating its ease of use and excellent results.

Download full-text PDF

Source
http://dx.doi.org/10.1002/dmrr.673DOI Listing

Publication Analysis

Top Keywords

blood glucose
12
glucose control
8
intensive care
8
insulin protocol
8
insulin flow
8
flow rate
8
glucose values
8
glucose
7
protocol
6
insulin
5