In this paper, we present a simple check valve whose operation mimics that of venous valves. Our check valve has a mono-leaflet and is constructed via an in situ fabrication method inside the PDMS platform. For the smooth operation of the valve's leaflet, the elasticity and the shape of the leaflet and the lubrication between the leaflet and the channel surface are important. We used 4-hydroxybutyl acrylate (4-HBA) as an elastic and photopolymerizable leaflet material. We mixed the triton X-100 with the 4-HBA pre-polymer solution for the adequate lubrication of the leaflet. We constructed the micro-pumping system by combining two venous-like check valves with an oscillating polymeric diaphragm driven by pneumatic force, and measured the flow rate according to the change of pumping frequency. We also investigated the pump's feasibility as a delivery system of biocompatible materials by using mouse embryo fibroblast cells.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/b606918e | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Institute of Humanoid Robots, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, P.R. China.
Magneto-responsive soft actuators hold significant promise in soft robotics due to their rapid responsiveness and untethered operation. However, controlling their deformations presents challenges because of their inherent flexibility and high degrees of freedom. Here, we present a magnetically driven bistable dome-shaped soft actuator that simplifies deformation by limiting it to two distinct states.
View Article and Find Full Text PDFEntropy (Basel)
November 2024
Faculty of Information Engineering, Quzhou College of Technology, Quzhou 324000, China.
Rolling bearings, as critical components of rotating machinery, significantly influence equipment reliability and operational efficiency. Accurate fault diagnosis is therefore crucial for maintaining industrial production safety and continuity. This paper presents a new fault diagnosis method based on FCEEMD multi-complexity low-dimensional features and directed acyclic graph LSTSVM.
View Article and Find Full Text PDFSci Rep
January 2025
College of Water Conservancy and Civil Engineering, Xinjiang Agricultural University, Urumqi, China.
A A Pract
December 2024
From the Department of Anesthesiology and Critical Care, All India Institute of Medical Sciences (AIIMS), Rishikesh, Uttarakhand, India.
The circle breathing system enables rebreathing using a carbon dioxide absorbent. This case report presents a rare incident of ventilation failure in a 30-year-old male patient due to a broken unidirectional valve in a soda lime canister. Despite the anesthesia machine passing automated checks, a mechanical blockage from caked soda lime in the inner inspiratory chamber led to insufficient tidal volume delivery.
View Article and Find Full Text PDFBMJ Case Rep
November 2024
Anesthesiology, Unidade Local de Saude de Coimbra, Coimbra, Portugal.
Hybrid procedures offer a promising solution for complex cases where open surgery is high risk, relying on the collaboration of anaesthesiologists, cardiac surgeons and interventional cardiologists. We present a male patient in his 70s with severe aortic stenosis, coronary artery disease, ascending aortic aneurysm and heart failure who underwent a hybrid cardiac procedure, including transcatheter aortic valve implantation, percutaneous coronary intervention of the right coronary artery and coronary artery bypass graft surgery. Through this hybrid intervention, involving a minimally invasive transcatheter and an open surgical procedure, the patient remained haemodynamically stable with minimal blood loss.