Fibrates, activators of the nuclear receptor PPARalpha, improve dyslipidemia, but their effects on insulin resistance and vascular disease are unresolved. To test the hypothesis that PPARalpha activation improves insulin resistance and vascular function, we determined the effects of fenofibrate in healthy adults with insulin resistance induced by short-term glucocorticoid administration. Eighteen normal-weight subjects were studied in four stages: at baseline, after 21 days of fenofibrate (160 mg/day) alone, after 3 days of dexamethasone (8 mg/day) added to fenofibrate, and after 3 days of dexamethasone added to placebo (dexamethasone alone). Dexamethasone alone caused hyperinsulinemia, increased glucose, decreased glucose disposal, and reduced insulin-induced suppression of hepatic glucose production as determined by hyperinsulinemic euglycemic clamp and increased systolic blood pressure as determined by ambulatory monitoring, features associated with an insulin-resistant state. Fenofibrate improved fasting LDL and total cholesterol in the setting of dexamethasone treatment but had no significant effect on levels of insulin or glucose, insulin-stimulated glucose disposal, or insulin suppression of glucose production during clamps, or ambulatory monitored blood pressure. In the absence of dexamethasone, fenofibrate lowered fasting triglycerides and cholesterol but unexpectedly increased systolic blood pressure by ambulatory monitoring. These data suggest that PPARalpha activation in humans does not correct insulin resistance induced by glucocorticoids and may adversely affect blood pressure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4303180 | PMC |
http://dx.doi.org/10.1152/ajpendo.00230.2006 | DOI Listing |
J Drug Target
January 2025
Department of Pharmaceutics, Sinhgad College of Pharmacy, Vadgaon (Bk.), Pune-411041, Maharashtra, India.
Ferulic acid (FA) is a phenolic compound obtained naturally and is a versatile antioxidant identified for its potential in managing hypertension. However, its application is constrained due to its classification as a BCS Class IV moiety. To address this, we concentrated on improving its solubility and permeability by developing nanostructured lipid carriers (NLCs) of FA using emulsification probe sonication technique.
View Article and Find Full Text PDFJ Cardiovasc Transl Res
January 2025
Duke University Medical Center, Durham, NC, 27710, USA.
Background: Non-invasive, continuous blood pressure monitoring technologies require additional validation beyond standard cuff-based methods. This study evaluates a non-invasive, multiparametric wearable cuffless blood pressure (BP) diagnostic monitor across all hypertension classes with diverse subjects.
Methods: A prospective, multicenter study assessed Nanowear's SimpleSense-BP performance, including induced and natural BP changes, significant BP variations (Systolic BP (SBP) ≥ ± 15 mm Hg and Diastolic BP (DBP) ≥ ± 10 mm Hg), and reference input value validity over 4 weeks.
Ann Intensive Care
January 2025
Jiangsu Provincial Key Laboratory of Critical Care Medicine, Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, No. 87, Dingjiaqiao Road, Gulou District, Nanjing, 210009, People's Republic of China.
Background: The association between bedside ventilatory parameters-specifically arterial carbon dioxide pressure (PaCO) and ventilatory ratio (VR)-and mortality in patients with acute respiratory distress syndrome (ARDS) remains a topic of debate. Additionally, the persistence of this association over time is unclear. This study aims to investigate the relationship between 28-day mortality in ARDS patients and their longitudinal exposure to ventilatory inefficiency, as reflected by serial measurements of PaCO and VR.
View Article and Find Full Text PDFSleep Breath
January 2025
Department of Pulmonary and Critical Care Medicine, Center of Respiratory Medicine, China-Japan Friendship Hospital, Beijing, China.
Background And Objective: There is no satisfactory treatment for obstructive sleep apnea (OSA) in patients with interstitial lung disease (ILD) because of poor tolerance of positive airway pressure (PAP) therapy. Supplemental oxygen therapy has been shown to reduce hypoxemia and is well tolerated in patients with ILD. However, little is known about the effect of nocturnal oxygen supplementation (NOS) on OSA in patients with ILD.
View Article and Find Full Text PDFEgypt Heart J
January 2025
Department of Cardiology, Division of Heart & Lungs, University Medical Center Utrecht, University of Utrecht, Utrecht, The Netherlands.
Background: Hyponatremia is one of the complicating findings in acute decompensated heart failure. Decrease in cardiac output and systemic blood pressure triggers activation of renin-angiotensin-aldosterone system, antidiuretic hormone, and norepinephrine due to the perceived hypovolemia. Fluid-overloaded heart failure patients are commonly treated with loop diuretics, acutely decompensated heart failure patients tend to be less responsive to conventional oral doses of a loop diuretic, while other different diuretics could work in different part of nephron circulation system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!