AI Article Synopsis

Article Abstract

A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography-mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R2=0.9932-1.0000), dynamic range (3 orders of magnitude), precision (4-9% RSD), as well as LOD (0.001-0.124 microg L(-1)) and LOQ (0.004-0.413 microg L(-1)), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 microg L(-1) in river water and 3.76, 13.25, and 0.10 microg L(-1) in fish serum, respectively. Natural steroid hormones estrone (E1), 17beta-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 microg L(-1) in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 microg L(-1), respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-006-0631-yDOI Listing

Publication Analysis

Top Keywords

microg l-1
24
steroid hormones
16
manual method
16
endocrine-disrupting chemicals
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
fully automated
8
method
8
automated method
8
on-fiber silylation
8

Similar Publications

Semi-aerobic Aged-refuse Bioreactor (SAARB) has a good effect on nitrogen removal in leachate, but a strong greenhouse gas (N2O) was generated during the nitrification and denitrification process. The effect of salinity (7-30 g x L(-1)) on the leachate treatment and the N2O production from SAARB system was investigated. Experimental results showed that salinity ranging from 7 to 30 g x L(-1) had no significant effect on COD removal, and the removal efficiency was always more than 85%.

View Article and Find Full Text PDF

In order to investigate the feasibility of deep denitrification and simultaneous removing phthalate esters (PAEs) in the process of reclaimed water treatment uses three-dimensional biofilm-electrode reactor coupled with sulfur autotrophic deep denitrification technology (3BER-S), the technological characteristics and mechanisms were analyzed based on determining the static adsorption capacity of biofilm cultured active carbon fillers in 3BER-S reactor together with the operation results of dynamic denitrification and simultaneous PAEs removing. The results showed that the average adsorption rates of DBP, DEHP were 85.84% and 97.

View Article and Find Full Text PDF

An analysis method has been established to test 27 elements (Li, Be, B, Mg, Al, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Sr, Mo, Cd, Sn, Sb, Ba, La, Hg, Pb, Bi) in Maca nationality's medicine with microwave digestion-ICP-MS. Sample solutions were analyzed by ICP-MS after microwave digestion, and the contents of elements were calculated according to their calibration curves, and internal standard method was adopted to reduce matrix effect and other interference effects. The experimental results showed that the linear relations of all the elements were very good; the correlation coefficient (r) was 0.

View Article and Find Full Text PDF

Based on indirect competitive immunoassay mechanism, bisphenol A (BPA) was detected by the evanescent wave all-fiber immunosensor previously developed with the detection limit of 0.2 microg x L(-1) and the linear detection range of 0.3-33.

View Article and Find Full Text PDF

In this paper, a method of determination of trace lead in water by UV-Visible diffuse reflectance spectroscopy combined with surfactant and membrane filtration enrichment was proposed. In the NH3 x H2O-NH4Cl buffer solution with pH 8.5, the lead(II) ion would react with dithizone to form the red complex under vigorous stirring, which is hydrophobic and can be enriched by the mixed cellulose ester membrane.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!