Assessment of the strength of minicapsulorhexes.

J Cataract Refract Surg

Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, Florida 33136, USA.

Published: August 2006

Purpose: To evaluate the effect of age, size, position, and species on the strength of minicapsulorhexes.

Setting: Surgical Suite and Laser Laboratory, Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, USA.

Methods: Capsulorhexes 0.7 to 2.3 mm in diameter were made centrally or peripherally in 35 eye-bank eyes and 32 rabbit eyes. A custom-made instrument stretched the capsulorhexes until rupture. Load and stretch at rupture were recorded.

Results: Maximum load and stretch were 26.3 mN +/- 20.3 (SD) and 50% +/- 18% for central and 50.8 +/- 20.5 mN and 69% +/- 17% for peripheral capsulorhexes in eye-bank eyes and 19.8 +/- 15.2 mN and 38% +/- 13% for central and 13.5 +/- 9.5 mN and 30% +/- 7% for peripheral capsulorhexes in rabbit eyes. Peripheral capsulorhexes were stronger and more elastic than central capsulorhexes in eye-bank eyes, and maximum load and stretch increased statistically with the capsulorhexis diameter.

Conclusions: Peripheral minicapsulorhexes were more resistant to rupture than central capsulorhexes in eye-bank eyes, probably because of increased lens capsule thickness at the periphery. An increase in capsulorhexis diameter increased the resistance to rupture.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2006.04.007DOI Listing

Publication Analysis

Top Keywords

eye-bank eyes
16
load stretch
12
peripheral capsulorhexes
12
capsulorhexes eye-bank
12
rabbit eyes
8
maximum load
8
+/-
8
central capsulorhexes
8
capsulorhexes
7
eyes
6

Similar Publications

Neurodegeneration in glaucoma patients is clinically identified through longitudinal assessment of structure-function changes, including intraocular pressure, cup-to-disc ratios from fundus images, and optical coherence tomography imaging of the retinal nerve fiber layer. Use of human post-mortem ocular tissue for basic research is rising in the glaucoma field, yet there are challenges in assessing disease stage and severity, since tissue donations with informed consent are often unaccompanied by detailed pre-mortem clinical information. Further, the interpretation of disease severity based solely on anatomical and morphological assessments by histology can be affected by differences in death-to-preservation time and tissue processing.

View Article and Find Full Text PDF

BACKGROUND Carotid artery injury has an incidence of 0.2% in the National Trauma Data Bank. The true incidence of intracranial carotid injury is unknown but can be estimated at less than one in 1000 trauma-related inpatient admissions in America.

View Article and Find Full Text PDF

Introduction: This study compared the clinical outcomes of allogenic cultured limbal epithelial transplantation (ACLET) and cultivated oral mucosal epithelial transplantation (COMET) in the management of limbal stem cell deficiency (LSCD).

Methods: Forty-one COMET procedures in 40 eyes and 69 ACLET procedures in 54 eyes were performed in the Corneoplastic Unit of Queen Victoria Hospital, East Grinstead. Data were examined for demographics, indications, ocular surface stability, absence of epithelial defect, ocular surface inflammation, visual outcomes, and intra- and postoperative complications.

View Article and Find Full Text PDF

Trabecular meshwork ultrastructural changes in primary and secondary glaucoma.

Sci Rep

January 2025

Ophthalmic Pathology Laboratory, L V Prasad Eye Institute, Kallam Anji Reddy Campus, 500034, Hyderabad, India.

To examine ultrastructural changes in the trabecular meshwork (TM) in patients with primary and secondary glaucoma using scanning electron microscopy (SEM). This was a qualitative descriptive hospital-based study on the ultrastructure of the TM. Pure TM samples were collected after microincisional trabeculectomy from 26 patients with primary or secondary glaucoma and 10 control samples from eye bank donor corneas.

View Article and Find Full Text PDF

The burden of medical contraindications to corneal donation: Time for review.

PLOS Glob Public Health

December 2024

Laboratory Biology, Engineering and Imaging for Ophthalmology, Health Innovation Campus, Faculty of Medicine, University Jean Monnet, Saint-Etienne, France.

Corneal graft (keratoplasty) is the most common allograft in the world, but the imbalance between the number of donors and the number of patients waiting for transplants is abysmal on a global scale and varies enormously from one country to another. The risk of transmission of systemic diseases from donor to recipient is demonstrably low. In over 50 years and an estimated 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!