Objectives: To study the normal Central Corneal Thickness (CCT) and investigate the correlation between CCT and age, gender intraocular pressure and refractive error

Material And Method: Population of age 12-60 years old were interviewed with standard questionnaire. Refractive error was measured and graded according to spherical equivalent power. Then intraocular pressure and central cornea thickness were measured by applanation tonometer and ultrasonic pachymeter, respectively. The data were analyzed using T-test, correlation and multivariate linear regression to identify mean CCT and correlation between age, gender, intraocular pressure, and refractive error.

Results: A total of 467 participants were enrolled into the study. One hundred and eighty-six (39.8%) were males and 281 (60.2%) were females. The average CCT was 535.2 +/- 29.9 microm. The mean CCT of right and left eyes were 535.3 +/- 30.4 microm, and 535.1 +/- 29.5 microm, respectively. The multivariate linear regression indicated that increasing in age would decrease the CCT 0.28 microm and an increasing of intraocular pressure would increase the CCT 1.4 microm statistically significance.

Conclusion: The CCT was independently related to the refractive error and gender Greater CCT was associated with higher intraocular pressure. Conversely, thinner cornea was correlated with older age group.

Download full-text PDF

Source

Publication Analysis

Top Keywords

intraocular pressure
24
age gender
12
gender intraocular
12
pressure refractive
12
refractive error
12
cct
9
central corneal
8
corneal thickness
8
12-60 years
8
multivariate linear
8

Similar Publications

Background: The present study aims to identify the relationship between longitudinal changes in corneal hysteresis (CH) and progressive retinal nerve fibre layer (RNFL) thinning in a cohort of medically controlled, early-to-moderate open-angle glaucoma (OAG) patients with a history of laser refractive surgery (LRS).

Methods: A total of 123 consecutive eyes with a diagnosis of medically controlled (peak intraocular pressure (IOP)<18 mm Hg), early-to-moderate OAG with a history of LRS underwent measurements of CH, corneal-compensated intraocular pressure (IOPcc) and RNFL thicknesses every 6 months. Linear models were used to investigate the relationship between CH change and RNFL thickness change over time.

View Article and Find Full Text PDF

Rapamycin protects glucocorticoid-induced glaucoma model mice against trabecular meshwork fibrosis by suppressing mTORC1/2 signaling.

Eur J Pharmacol

January 2025

Affiliated Eye Hospital of Nanchang University, Jiangxi Medical College, Nanchang University, Jiangxi Research Institute of Ophthalmology & Visual Science, Jiangxi Provincial Key Laboratory for Ophthalmology, Jiangxi Clinical Research Center for Ophthalmic Disease, Nanchang, China. Electronic address:

Systemic or local use of glucocorticoids (GCs) can induce pathological elevation of intraocular pressure (IOP), potentially leading to permanent visual loss. Previous studies have demonstrated that rapamycin (Rapa) inhibits the activation of retinal glial cells and the production of neuroinflammation, achieving neuroprotective goals. However, there has been little research on the effect of Rapa on the trabecular meshwork (TM).

View Article and Find Full Text PDF

Animal models that help us understand how elevated intraocular pressure (IOP) causes axonal injury will lead to new glaucoma therapies. Because reliable measurements are difficult to obtain in chronic models, we developed the controlled elevation of IOP (CEI) approach. Here, a cannula connected to an elevated balanced salt solution (BSS) reservoir is inserted into the anterior chamber of anesthetized Brown Norway rats.

View Article and Find Full Text PDF

Objective: To obtain standard reference values of intraocular pressure measured with rebound tonometry in conscious healthy Egyptian vultures (Neophron percnopterus).

Methods: 17 Egyptian vultures presented for a routine health check, involving a full physical examination, blood film examination, Hct, manual total leukocyte count, and plasma biochemistry. 15 animals considered healthy and with no signs of stress underwent an ophthalmic examination, including observation of facial symmetry, adnexa, and direct fundoscopy to screen for ocular disease.

View Article and Find Full Text PDF

Purpose: To describe effects of sustained-release steroid delivery devices on intraocular pressure (IOP) in eyes with glaucoma drainage devices (GDD).

Methods: Retrospective case series of eyes with steroid implants (dexamethasone or fluocinolone acetonide) and prior GDD (Ahmed, Baerveldt) without uveitis. Outcomes included IOP, IOP rise, central foveal thickness (CFT), and IOP medications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!