A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of thermal cycling on bond strengths of single-step self-etch adhesives to bovine dentin. | LitMetric

The purpose of this study was to clarify the effect of thermal cycling on dentin bond strengths of single-step self-etch adhesives. Five commercially available single-step self-etch systems were used. The adhesives were applied to the dentin surfaces of bovine incisors, and then light-irradiated. Resin composites were condensed into a mold and light-irradiated. Bonded specimens were divided into two groups and stored in water at 37 degrees C for 24 h without thermal cycling, or in water at 37 degrees C for 24 h followed by 10,000 thermal cycles between 5 degrees C and 60 degrees C. Ten samples per group were tested for shear strength at a crosshead speed of 1.0 mm/min. The data were analyzed by Student's t test and Tukey HSD test at a probability level of 0.05. After 24 h of storage in water, the mean dentin bond strengths ranged from 9.3 MPa to 14.0 MPa. After 10,000 thermal cycles, the mean bond strengths remained unchanged. Failure after the test was commonly due to adhesive breakdown associated with partial cohesive failure of the resin. The present results suggest that the benefit of using single-step self-etch systems, in terms of simplifying the clinical procedure, might be acceptable even after thermal stresses.

Download full-text PDF

Source
http://dx.doi.org/10.2334/josnusd.48.63DOI Listing

Publication Analysis

Top Keywords

bond strengths
16
single-step self-etch
16
thermal cycling
12
strengths single-step
8
self-etch adhesives
8
dentin bond
8
self-etch systems
8
water degrees
8
10000 thermal
8
thermal cycles
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!