Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs.

Can J Vet Res

Department of Physiology and Pharmacology, College of Veterinary Medicine, University of Georgia, Athens 30602, USA.

Published: July 2006

To assess the accuracy and precision of indirect measurements of systemic arterial blood pressure (BP), results obtained with an oscillometric device (BPo) and a Doppler ultrasonic device (BPud) were compared with those obtained by direct radiotelemetry (BPrt) in 12 conscious beagles. The correlation between indirectly obtained and directly measured values for BP parameters ranged widely for the different indirect methods and sites of cuff placement, with R2 between 0.001 and 0.901. Both indirect methods underestimated all BP parameters, the degree of underestimation increasing at higher values for the BP. The highest correlation occurred when estimates were the average of 5 values consecutively obtained with the oscillometric device and cuff placement at the coccygeal artery (R2 = 0.854 for mean BPo, 0.886 for systolic BPo, and 0.901 for diastolic BPo; P < 0.0001 for all parameters) or with the ultrasonic Doppler device at the metatarsal arteries (R2 = 0.810 for systolic BPud; P < 0.0001). Multiple consecutively obtained values are advised, as this approach improves the reliability of indirect BP measurements. The strong correlation between directly measured values and estimates derived as the average of 5 consecutive indirectly obtained values indicates that the latter approach provides a useful estimate of BP in conscious dogs and is likely to be useful in monitoring disease progress and treatment in dogs with abnormal BP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1477936PMC

Publication Analysis

Top Keywords

doppler ultrasonic
8
blood pressure
8
conscious dogs
8
indirect measurements
8
oscillometric device
8
directly measured
8
measured values
8
indirect methods
8
cuff placement
8
values
6

Similar Publications

Treating colorectal liver metastases (CLMs) located at the hepatocaval confluence with surgery is challenging due to its complexity and associated high risks of perioperative mortality and morbidity. Moreover, thermal ablation techniques are sensitive to the "heat-sink" effect, which reduces their efficacy when tumors are in contact with major blood vessels. In this study we evaluated the feasibility and safety of an intraoperative high-intensity focused ultrasound (HIFU) device for destroying liver tissue volumes sufficiently large to consider treating CLMs at the hepatocaval confluence.

View Article and Find Full Text PDF

Aim: This study investigated the major factors contributing to the missed diagnosis of total anomalous pulmonary venous connection (TAPVC) in fetal echocardiography.

Methods: We retrospectively analyzed the prenatal ultrasonic images of 32 fetuses with missed diagnoses of TAPVC, compared them with autopsy and postnatal surgical records, and summarized the most likely reasons leading to the missed diagnoses.

Results: We studied a total of 157 fetuses with TAPVC, 32 (20.

View Article and Find Full Text PDF

Objective: To construct and validate a new thyroid imaging reporting and data system (TI-RADS) based on radiating blood flow and grayscale US features.

Materials And Methods: This study enrolled patients from 4 hospitals from January 2018 to November 2023 retrospectively and prospectively. All US features associated with malignant thyroid nodules were assessed by multivariable logistic regression to construct baseline US TI-RADS (BUS TI-RADS), which was tested with internal validation set, external validation set and prospective validation set.

View Article and Find Full Text PDF

The value of ultrasound spectra of middle cerebral artery and umbilical artery blood flow in adverse pregnancy outcomes.

J Perinat Med

November 2024

Gynecologic, Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, Wuhan, Hubei, China.

Objectives: To evaluate the diagnostic value of ultrasound spectra of the middle cerebral artery (MCA) and umbilical artery (UA) blood flow in predicting adverse pregnancy outcomes.

Methods: Data from 202 late singleton pregnancies (32-34 weeks gestation) were analyzed. Group A included 155 normal pregnancies, while Group B comprised 47 high-risk pregnancies.

View Article and Find Full Text PDF

[Use of ultrasound in vein of Galen malformation].

Rev Med Inst Mex Seguro Soc

November 2024

Instituto Mexicano del Seguro Social, Centro Médico Nacional La Raza, Unidad Médica de Alta Especialidad No. 3 Dr. Victor Manuel Espinosa De Los Reyes Sanchez, División de Pediatría. Ciudad de México, México.

Background: Aneurysmal malformation of the vein of Galen (AVMG) is a rare malformation of the intracranial venous system. The incidence is estimated at 1:10,000-25,0000 births. The clinical picture is very variable, in the neonatal period it includes seizures and heart failure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!