A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Precision and accuracy of two blood glucose meters: FreeStyle Flash versus One Touch Ultra. | LitMetric

Purpose: The precision and accuracy of two blood glucose meters were evaluated using finger and forearm blood samples.

Methods: Duplicate blood glucose measurements on the same forearm and finger as venipuncture were performed with the FreeStyle Flash and the One Touch Ultra. Accuracy was assessed by error-grid analysis and the number of values within 10% of the laboratory reference value. Precision was determined by calculating the absolute mean percent differences in glucose values between the first and second fingers and forearm test results. Forearm testing success was defined as an accurate glucose reading obtained with one lance.

Results: A total of 100 patients completed the study; 93% had diabetes and 53% were female. Patients' mean +/- S.D. age was 63 +/- 12 years, and glucose measurements ranged from 69 to 354 mg/dL. All finger-stick samples fell within error-grid zones A and B; 72% and 57% of FreeStyle Flash and One Touch Ultra values fell within 10% of the laboratory reference values, respectively (p = 0.027). Forearm samples were successfully obtained in 99 and 74 patients using the FreeStyle Flash and One Touch Ultra (p < 0.001), with 64 and 36 samples, respectively, falling within 10% of the laboratory reference values (p = 0.035). There was no difference in meter precision.

Conclusion: The FreeStyle Flash and the One Touch Ultra are precise glucose meters; however, the FreeStyle Flash was associated with greater accuracy. Success rates of forearm glucose sampling were significantly greater when the FreeStyle Flash meter was used.

Download full-text PDF

Source
http://dx.doi.org/10.2146/ajhp050473DOI Listing

Publication Analysis

Top Keywords

freestyle flash
28
touch ultra
20
flash touch
16
blood glucose
12
glucose meters
12
10% laboratory
12
laboratory reference
12
precision accuracy
8
accuracy blood
8
glucose
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!