Introduction: The objectives of this study were to evaluate, through panoramic radiographs, the mesiodistal axial inclinations of the maxillary anterior teeth at the beginning and end of nonextraction orthodontic treatment, and to compare the results with the mesiodistal axial inclinations of a control sample with normal (acceptable) occlusions.

Methods: The experimental sample consisted of 40 white patients (20 male, 20 female; mean age, 14 years) with Class I maloccusions who were treated orthodontically with a standard edgewise (not preadjusted) technique without extractions. The mean treatment period was 1.6 years. The control sample comprised 42 white subjects (14 male, 28 female; age range, 12-17 years) with untreated normal (acceptable) occlusions. Panoramic radiographs were taken of the patients at the beginning (T1) and end (T2) of treatment. The mean values of the mesiodistal axial inclination at T1 were compared with the mean values at T2, and both were compared with the mesiodistal axial inclinations of the control sample.

Results: The mesiodistal axial inclinations of the maxillary anterior teeth of the experimental group at T1 were different from those of the control group for 50% of the evaluated teeth. In contrast, the inclinations at T2 were consistent with the normal anatomical configuration of the controls.

Conclusions: The panoramic radiograph is an effective tool for evaluating the mesiodistal axial inclinations of maxillary anterior teeth.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2006.03.001DOI Listing

Publication Analysis

Top Keywords

mesiodistal axial
28
axial inclinations
24
inclinations maxillary
16
maxillary anterior
16
anterior teeth
16
panoramic radiographs
8
inclinations control
8
control sample
8
normal acceptable
8
male female
8

Similar Publications

Aim: To compare the microleakage in class V cavities restored with Activa Bioactive Restorative, Activa Pronto, and nanohybrid composite.

Materials And Methods: Standardized class V cavity preparations (mesiodistal: 3 mm; occlusocervical: 2 mm; axial depth: 1 mm) were made on the buccal surface of 60 extracted intact maxillary premolar teeth. The preparations were divided into three experimental groups ( = 20) depending on the restorative material used.

View Article and Find Full Text PDF

Correlation between implant angulation and crestal bone changes: A 5-year retrospective study.

J Prosthet Dent

January 2025

Associate Professor, Department of Prosthodontics, School of Dentistry, Kyung Hee University, Seoul, Republic of Korea. Electronic address:

Statement Of Problem: The effects of nonaxial forces on peri-implant bone loss have been investigated, mostly in reference to buccal mesiodistal implant angulations as potential risk indicators. However, when implant angulations are multidirectional, including the buccolingual aspect, evaluations of peri-implant bone loss based solely on mesiodistal measurements may skew the correlation.

Purpose: The purpose of this retrospective study was to evaluate the correlation between the magnitudes of multidirectional implant angulations and peri-implant crestal bone loss.

View Article and Find Full Text PDF

Aim: The present study aims to describe an in-house protocol for fully guided zygomatic implant surgery and prosthesis repositioning.

Materials And Methods: Four extramaxillary zygomatic dental implants (ZIs) were placed in one patient. The preoperative phase included digital planning, through which a surgical guide was designed and created.

View Article and Find Full Text PDF

Introduction: Successful endodontic treatment depends on completely clearing, shaping, and filling the prepared canals. Knowledge of the common and aberrant varying pulp anatomies is essential for suitable root canal treatment. Since, this anatomy is complex and varies morphologically in different populations.

View Article and Find Full Text PDF

Objective: The study employed three-dimensional (3D) finite element analysis (FEA) and examined how implant diameters affect stress distribution across the implant-bone contact and how stress transmission through this interface changes during axial and non-axial loading.

Materials And Methods: A 3D mandibular model was created using cone beam CT of a patient with implants inserted into the first mandible molar. Nobel Biocare implants (Nobel Biocare, Switzerland) with specific dimensions of 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!