Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: Although previous generations of multislice computed tomography (CT) have demonstrated accurate detection of obstructive bypass graft disease, progression of coronary disease is a more frequent cause for ischaemic symptoms late after bypass graft surgery. We explored the diagnostic performance of 64-slice CT in symptomatic patients after bypass surgery, for the assessment of both grafts and native coronary arteries.
Methods And Results: The 64-slice CT angiography (Siemens Sensation 64, Germany) was performed in 52 symptomatic patients, 10 +/- 5 years after bypass surgery. Two independent, blinded observers assessed all grafts and coronary arteries for stenosis, using conventional quantitative angiography as a reference. A total of 109 grafts (182 graft segments), 123 distal coronary run-offs, and 116 non-bypassed coronary branches (288 segments) were analysed. Per-segment detection of graft disease yielded a sensitivity of 99% (71/72) and specificity of 96% (106/110). Sensitivity and specificity to detect run-off disease were 89% (8/9) and 93% (106/114), positive predictive value was 50% (8/16). In non-grafted coronary segments, CT detected significant stenosis with a sensitivity and specificity of 97% (62/64) and 86% (192/224). Overestimation occurred more frequently in calcified segments (P = 0.002).
Conclusion: The 64-slice CT allows angiographic evaluation of grafts and coronary arteries, although overestimation of coronary obstruction occurs, particularly in the presence of calcified disease.