Study Design: In vitro biomechanical investigation of 1 and 2-screw anterior scoliosis constructs with varying screw diameters.
Objective: To determine a possible optimal configuration of screw number and diameter at varying levels within the thoracic spine for anterior vertebral body fixation.
Summary Of Background Data: Single-rod systems are typical in anterior thoracic and thoracolumbar correction of adolescent idiopathic scoliosis; although dual rod systems may offer more flexural stability. Loss of fixation remains problematic, particularly in the proximal thoracic vertebrae, and it remains unclear how screw diameter or the number of screws within the vertebrae affect fixation.
Methods: Individual vertebral levels from 10 cadaveric thoracic spines were randomly assigned to either 1 or 2 screws of 5, 6, or 7-mm diameter. Bone-screw interface failures were created in coronal plane cantilever plow, and failure loads were compared across vertebral levels for each instrumentation method.
Results: Two-screw constructs had significantly higher failure loads than single-screw constructs, while increasing screw diameter also produced significant changes in fixation strength. Two-screws had improved performance in the mid and lower thoracic spine, while a single screw was more stable in the upper thoracic spine.
Conclusions: Failure modes for 1-screw constructs almost entirely (89%) showed gradual plowing through the bone, whereas acute fracture through the vertebral body or pedicles were common forms of failure (85%) for 2-screw constructs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.brs.0000225997.41924.eb | DOI Listing |
Cureus
November 2024
Aerospace Engineering, Universiti Putra Malaysia, Kuala Lumpur, MYS.
Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.
View Article and Find Full Text PDFVet Comp Orthop Traumatol
December 2024
Surgery Department, Evidensia Dierenziekenhuis Hart van Brabant, Waalwijk, Brabant, The Netherlands.
Objective: To describe percutaneous fluoroscopy-guided placement of self-drilling, self-tapping, 3.0 mm cannulated headless compression screws (HCS) for surgical reduction of sacroiliac luxation (SIL) in cats, and to document clinical outcome.
Materials And Methods: Medical records of cats with SIL, managed by percutaneous fluoroscopy-guided placement of a 3.
Materials (Basel)
November 2024
Department of Furniture Design, Faculty of Forestry and Wood Technology, Poznań University of Life Sciences, 60-637 Poznań, Poland.
Many factors affect screw withdrawal resistance (SWR), including screw size, embedment depth, the pre-drilled hole's diameter, dimensional accuracy, and the furniture pieces' material properties being joined. While prior research has extensively examined the influence of these factors, this study aimed to explore a neglected factor: how drill bit wear impacts pilot hole quality and subsequent SWR. The experimental setup included pinewood samples with pre-drilled 5 mm diameter blind pilot holes with a depth of 45 mm.
View Article and Find Full Text PDFPolymers (Basel)
December 2024
Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, MI 48824, USA.
In this study, water-insoluble, moisture-resistant starch foams were prepared using an optimized one-step extrusion-foaming process in a ZSK-30 twin screw extruder. The extrusion parameters, including temperature, screw configuration, die diameter, water content, and feeding rates, were optimized to achieve foams with the lowest density and controlled expansion. A screw configuration made up of three kneading sections was found to be the most effective for better mixing and foaming.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Professor and Director, Advanced Specialty Education Program in Prosthodontics, Loma Linda University School of Dentistry, Loma Linda, Calif.
Removing a fractured implant screw, though a relatively rare occurrence, presents a significant challenge for clinicians. Protecting the internal surface of the implant from damage during the retrieval of the fractured fragment is critical to avoid additional complications. A novel, cost-effective, and conservative technique for retrieving fractured implant screws using a small-diameter dental prophylactic brush is described.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!