Background: Both intravascular ultrasound and optical coherence tomography have been purported to accurately detect and characterize coronary atherosclerotic plaque composition. The aim of our study was to directly compare the reproducibility and diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of coronary plaque composition ex vivo as compared with histology.

Methods And Results: Intravascular ultrasound (20 MHz) and optical coherence tomography imaging was performed in eight heart specimens using motorized pullback. Standard histology using hematoxylin-eosin and van Gieson staining was performed on 4 mum thick slices. Each slice was divided into quadrants and accurately matched cross-sections were analyzed for the presence of fibrous, lipid-rich, and calcified coronary plaque using standard definitions for both intravascular ultrasound and optical coherence tomography and correlated with histology. After exclusion of 145/468 quadrants, we analyzed the remaining 323 quadrants with excellent image quality in each procedure. Optical coherence tomography demonstrated a sensitivity and specificity of 91/88% for normal wall, 64/88% for fibrous plaque, 77/94% for lipid-rich plaque, and 67/97% for calcified plaque as compared with histology. Intravascular ultrasound demonstrated a sensitivity and specificity of 55/79% for normal wall, 63/59% for fibrous plaque, 10/96% for lipid-rich plaque, and 76/98% for calcified plaque. Both intravascular ultrasound and optical coherence tomography demonstrated excellent intraobserver and interobserver agreement (optical coherence tomography: kappa=0.90, kappa=0.82; intravascular ultrasound: kappa=0.87, kappa=0.86).

Conclusion: Optical coherence tomography is superior to intravascular ultrasound for the detection and characterization of coronary atherosclerotic plaque composition, specifically for the differentiation of noncalcified, lipid-rich, or fibrous plaque.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00019501-200608000-00005DOI Listing

Publication Analysis

Top Keywords

optical coherence
36
coherence tomography
36
intravascular ultrasound
36
plaque composition
16
ultrasound detection
12
detection characterization
12
plaque
12
atherosclerotic plaque
12
ultrasound optical
12
fibrous plaque
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!