Mini external fixation for hand fractures and dislocations: The current state of the art.

Hand Clin

Department of Orthopaedics and Traumatology, Cliniques Universitaires de Bruxelles, Hôpital Erasme, ULB 808 Route de Lennik 1070, Brussels, Belgium.

Published: August 2006

External fixation devices for the hand provide a versatile approach to various hand injuries. Some fractures and dislocations urge the use of an external minifixation; in other fractures, external minifixation must be seen as an alternative or companion to other methods of hand stabilization. MiniFix is useful to maintain or restore hand function and hand anatomy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hcl.2006.02.014DOI Listing

Publication Analysis

Top Keywords

external fixation
8
fractures dislocations
8
external minifixation
8
hand
6
mini external
4
fixation hand
4
hand fractures
4
dislocations current
4
current state
4
state art
4

Similar Publications

Identifying a Reliable Intra-articular Landmark to Avoid Vascular Injury During Transacetabular Screw Fixation: A 3D Computed Tomography Study.

J Am Acad Orthop Surg

September 2024

From the Department of Orthopaedic Surgery, Keck Medical Center of the University of Southern California, Los Angeles, CA (Ihn, Chung, Lovro, Patterson, Christ, and Heckmann), the Department of Orthopaedic Surgery, Mayo Clinic, Rochester, MN (Chen), the Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA (Tucker), and the Department of Radiology, Keck Medical Center of the University of Southern California, Los Angeles, CA (White, and Hwang).

Introduction: Vascular injury during acetabular screw fixation is a life-threatening complication of total hip arthroplasty. This study uses three-dimensional computed tomography to (1) measure absolute distance from the external iliac artery (EIA) to the acetabulum, (2) determine available bone stock along the EIA path, and (3) create a novel acetabular vascular risk map.

Methods: A retrospective radiographic study was conducted using three-dimensional CT.

View Article and Find Full Text PDF

Association Between Nail Type and Aseptic Revision Risk After Cephalomedullary Nailing for Hip Fracture.

J Bone Joint Surg Am

January 2025

Surgical Outcomes and Analysis Department, Kaiser Permanente, San Diego, California.

Background: Although the majority of intertrochanteric femoral fractures in the United States are now treated with cephalomedullary nailing, it remains uncertain whether differences in clinical performance by nail type exist. The purpose of this study was to compare the aseptic revision rates associated with the 3 most commonly utilized cephalomedullary nails in the United States today: the Gamma nail (Stryker), the INTERTAN (Smith+Nephew), and the Trochanteric Fixation Nail/Trochanteric Fixation Nail Advanced (TFN/TFNA; DePuy Synthes).

Methods: Using an integrated health-care system's hip fracture registry, patients ≥60 years of age who were treated with 1 of these 3 commonly used cephalomedullary nail devices were identified.

View Article and Find Full Text PDF

Background: In the setting of cervical open-door laminoplasty, the question of whether or not every opened laminar level should be instrumented has not been sufficiently investigated. We postulated that the surgical outcomes of open-door laminoplasty with instrumentation of every second opened level (skip-fixation) might not be inferior to those of laminoplasty with instrumentation of every opened level (all-fixation). The purpose of the present study was to test the noninferiority of laminoplasty with skip-fixation in improving myelopathy at 2 years postoperatively compared with all-fixation.

View Article and Find Full Text PDF

Molecular dynamics of photosynthetic electron flow in a biophotovoltaic system.

Environ Sci Ecotechnol

January 2025

Systems Biotechnology Group, Department of Microbial Biotechnology, Helmholtz Centre for Environmental Research - UFZ, 04318, Leipzig, Germany.

Biophotovoltaics (BPV) represents an innovative biohybrid technology that couples electrochemistry with oxygenic photosynthetic microbes to harness solar energy and convert it into electricity. Central to BPV systems is the ability of microbes to perform extracellular electron transfer (EET), utilizing an anode as an external electron sink. This process simultaneously serves as an electron sink and enhances the efficiency of water photolysis compared to conventional electrochemical water splitting.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!