Objectives: This study sought to evaluate the effectiveness and safety of the sirolimus-eluting stent in the treatment of in-stent restenosis (ISR) in consecutive unselected patients undergoing coronary intervention in a real-world scenario.

Background: Restenosis after bare metal stenting is characterized by a high rate of re-restenosis once treated with repeated percutaneous coronary intervention.

Methods: The study was designed as a prospective two-center registry. We enrolled 244 patients with ISR in a native coronary artery or saphenous vein graft who had clinical indication for repeat intervention.

Results: Sirolimus stent implantation was successful in all lesions. At 9-month follow-up, death occurred in 4 (1.6%) patients, myocardial infarction in 4 (1.6%), and ischemia-driven target lesion revascularization (TLR) in 12 (4.9%), for a cumulative event-free survival of 227 (93%). Although 9-month follow-up angiography was planned in all patients, only 150 (62%) patients completed it, and restenosis was present in 13 (8.7%) patients. Diabetes and non-ST-segment elevation acute coronary syndrome at presentation were the only independent predictors of freedom from ischemia-driven TLR and major adverse cardiac events.

Conclusions: Sirolimus stent implantation for the treatment of ISR is effective and safe. In diabetic patients and in those with acute coronary syndrome, the higher rate of recurrence requires further evaluation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2006.03.039DOI Listing

Publication Analysis

Top Keywords

sirolimus stent
12
stent implantation
12
in-stent restenosis
12
effectiveness safety
8
9-month follow-up
8
acute coronary
8
coronary syndrome
8
patients
7
coronary
6
restenosis
5

Similar Publications

Background: The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis. AVF stenosis is a common complication, often requiring balloon angioplasty. For recurrent stenosis, AVF stenting may be an option.

View Article and Find Full Text PDF

Background: First-generation bioresorbable scaffolds (BRS) increased risks of stent thrombosis and adverse events. The Bioheart scaffold is a new poly-L-lactic acid-based BRS.

Objectives: This study sought to evaluate the efficacy and safety of the BRS in patients with coronary artery disease.

View Article and Find Full Text PDF

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF

Efficacy and Safety of Sirolimus-Coated Balloon Angioplasty in De Novo Lesions in Large Coronary Vessels: A Propensity Score-Matched Study.

Catheter Cardiovasc Interv

January 2025

Department of Cardio-Thoracic-Vascular Diseases, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Background: Evidence regarding drug-coated balloon (DCB)-only angioplasty in de novo lesions of large vessels is still limited and mainly focused on paclitaxel-coated balloon. We aimed to analyze the safety and efficacy of sirolimus-coated balloon (SCB)-only angioplasty in de novo lesions in large vessels compared to drug-eluting stent (DES).

Methods: In this retrospective, dual-center, case-control study, we enrolled all consecutive patients treated between January 2022 and January 2024 with SCB-only angioplasty in de novo lesion in large vessel (> 2.

View Article and Find Full Text PDF

Background: Few data are available on polymer-free drug-eluting stents in patients undergoing percutaneous coronary intervention (PCI).

Aims: We aimed to determine the efficacy and safety of a polymer-free amphilimus-eluting stent (AES), using a reservoir-based technology for drug delivery, compared with a biodegradable-polymer everolimus-eluting stent (EES).

Methods: This was a randomised, investigator-initiated, assessor-blind, non-inferiority trial conducted at 14 hospitals in Italy (ClinicalTrials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!