Multiplexed rectilinear ion trap mass spectrometer for high-throughput analysis.

Anal Chem

Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907-2084, USA.

Published: July 2006

A multichannel mass spectrometer based on the rectilinear ion trap (RIT) analyzer was designed and constructed for simultaneous high-throughput analysis of multiple samples. The instrument features four parallel ion source/mass analyzer/detector channels assembled in a single vacuum chamber and operated using a common set of control electronics, including a single rf amplifier and transformer coil. This multiplexed RIT mass spectrometer employs an array of four millimeter-sized ion traps (x(o) = 5.0 mm and y(o) = 4.0 mm, where x(o) and y(o) are the half-distances in the x and y dimensions, respectively). Mass spectra are acquired from four different samples simultaneously. The available mass/charge range is m/z 15-510 with excellent linearity of the mass calibration (R2 = 0.999 999). The peak width is less than 0.3 mass/charge units at m/z 146, corresponding to a resolution of approximately 500. Simultaneous MS/MS of ions due to four compounds (3-fluoroanisole, 4-fluoroanisole, 2-fluorobenzyl alcohol, 2,6-dimethylcyclohexanone) with the same nominal molecular radical cation but distinctive fragmentation patterns was demonstrated. Isolation and fragmentation efficiencies were approximately 25 and approximately 75%, respectively, measured in the typical case of the molecular radical cation of acetophenone. Preacquisition differential data were obtained by real-time subtraction of the ion signals from two channels of the multiplexed mass spectrometer. The differential experiment presented offers proof of principle of comparative mass spectra in high-throughput screening applications while reducing data storage requirements.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac060149eDOI Listing

Publication Analysis

Top Keywords

mass spectrometer
16
rectilinear ion
8
ion trap
8
high-throughput analysis
8
mass spectra
8
molecular radical
8
radical cation
8
mass
7
ion
5
multiplexed rectilinear
4

Similar Publications

Development and validation of an LC-MS/MS method for quantifying total and unbound doravirine in human plasma.

J Chromatogr B Analyt Technol Biomed Life Sci

December 2024

Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, Cape Town, South Africa. Electronic address:

A robust LC-MS/MS method was developed to quantify total and unbound doravirine in plasma samples from patients receiving daily doses of 100 mg doravirine, in combination with lamivudine and tenofovir disoproxil fumarate, in a phase 3 clinical trial. The trial is ongoing, and sample analysis is planned to commence once all samples have been collected. The method was validated to quantify both total and unbound doravirine using a single calibration curve.

View Article and Find Full Text PDF

Background: Apolipoprotein ε4 (APOE4) is a major risk factor for Alzheimer's disease (AD). APOE4 carriers display altered whole-body metabolism, including increased blood glucose and inuslin. Although conditions affecting whole-body metabolism like obesity and diabetes are AD risk factors, knowledge regarding the contribution of peripheral tissues to this effect is minimal.

View Article and Find Full Text PDF

Background: Despite being the most common cause of dementia worldwide, the mechanisms underlying the progression of Alzheimer's disease (AD) are not clear and effective treatments are still needed. Hence, further investigation regarding the pathogenesis of AD is required, which might allow for a better understanding of the disease, as well as for an early diagnosis of AD, thus improving the clinical management of AD patients. Here, to identify key proteins in AD pathogenesis, we performed two proteomics strategies, TMT (Tandem Mass Tags) 10-plex quantitative proteomics and LFQ (Label Free Quantification).

View Article and Find Full Text PDF

A portable gas chromatograph-mass spectrometer (GC-MS) is an effective instrument for rapid on-site detection of volatile organic compounds (VOCs). Current instruments typically adsorb samples at ambient temperature, challenging the detection of low-boiling VOCs. In this study, a low-temperature adsorption thermal desorption method is proposed for sample enrichment in a portable GC-MS.

View Article and Find Full Text PDF

A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.

Biomed Chromatogr

February 2025

Yangzhou University Medical College, Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Institute of Translational Medicine, Yangzhou University, Yangzhou, Jiangsu Province, China.

Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C column coupled to a triple quadrupole mass spectrometer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!