A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Chromotropic acid-functionalized polyurethane foam: A new sorbent for on-line preconcentration and determination of cobalt and nickel in lettuce samples. | LitMetric

Chromotropic acid-functionalized polyurethane foam: A new sorbent for on-line preconcentration and determination of cobalt and nickel in lettuce samples.

J Sep Sci

Núcleo de Química Analítica da Bahia, Laboratório de Química Analítica, Universidade Estadual do Sudoeste da Bahia, Campus de Jequié, Jequié-BA, Brazil.

Published: June 2006

A chromotropic acid-functionalized polyurethane foam has been developed for use in an on-line preconcentration system for cobalt and nickel determination. The packing material was prepared by covalent coupling of chromotropic acid with the polyurethane foam through an azo group. Co and Ni ions were sorbed in the mini-column, from which they could be eluted directly to the nebulizer-burner system of a flame atomic absorption spectrometer. Elution of cobalt and nickel from the mini-column can be accomplished with 0.50 and 0.75 M HCl solutions, respectively. The enrichment factors obtained were 22 (Co) and 27 (Ni), for 60 s preconcentration time, and 57 (Co) and 59 (Ni), if a preconcentration time of 180 s was used. Under the optimum conditions, the proposed procedure allowed the determination of metals with detection limits of 0.43 (cobalt) and 0.52 microg/L (nickel), respectively, on using preconcentration periods of 180 s. The accuracy of the developed procedure was evaluated by analysis of the certified reference materials NIST 1515 Apple Leaves and NIST 1570a Spinach Leaves. The method was applied to the analysis of lettuce samples. The contents of cobalt in the samples analyzed varied from 0.75 to 0.98 microg/g. Nickel was not detected in the lettuce samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.200600079DOI Listing

Publication Analysis

Top Keywords

polyurethane foam
12
cobalt nickel
12
lettuce samples
12
chromotropic acid-functionalized
8
acid-functionalized polyurethane
8
on-line preconcentration
8
preconcentration time
8
preconcentration
5
cobalt
5
nickel
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!