This study investigated the effect of two base materials with different elastic moduli (F2000 and Vitrebond) on the fracture load of machinable ceramic inlays. Standardized MOD cavities were prepared in 18 human maxillary first or second premolars. The teeth were randomly assigned to three groups of six premolars each; Group 1 (control: no base); Group 2 (base with a polyacid-modified resin composite: F2000); Group 3 (base with a resin-modified glass-ionomer cement: Vitrebond). The inlays were fabricated from Vitablocs Mark II using a Cerec II machine. After the inlays were cemented with Tetric Ceram and the Syntac adhesive system, using the Ultrasonic Insertion Technique (USI), they were stored in distilled water at 37 degrees C for 24 hours prior to fracture testing in a universal testing machine using a crosshead speed of 0.5 mm/minute. The static transverse elastic moduli of base materials were measured using a three-point bending test. The mean fracture loads and standard deviations of the Cerec inlays in Groups 1, 2 and 3 were 1.15 +/- 0.39 KN, 1.13 +/- 0.36 KN and 0.58 +/- 0.11 KN, respectively. Statistical analysis showed that the mean fracture load of Group 3 was significantly lower than that of Groups 1 and 2 (p < .05). There was no significant difference in fracture load between Groups 1 and 2. The means and standard deviations of the elastic moduli of F2000 and Vitrebond were 15.63 +/- 0.32 and 2.16 +/- 0.55 GPa, respectively. The results indicated that the fracture load increased significantly as the elastic modulus of a base material increased.

Download full-text PDF

Source
http://dx.doi.org/10.2341/05-3DOI Listing

Publication Analysis

Top Keywords

elastic moduli
16
fracture load
16
base materials
12
materials elastic
8
fracture loads
8
machinable ceramic
8
ceramic inlays
8
moduli f2000
8
f2000 vitrebond
8
group base
8

Similar Publications

Article Synopsis
  • Incorporating nanomaterials into hydrogels allows for the creation of customizable materials with adjustable properties based on their nanoscale structures.
  • This study explores the relationship between the structural arrangement and properties of a composite hydrogel made from thermoresponsive polymer, gelatin, and antimicrobial light-responsive gold nanorods (PAuNRs).
  • Findings indicate that the addition of PAuNRs leads to a softer hydrogel with reduced elasticity, which can be tailored for specific biomedical applications like tissue engineering and drug delivery.
View Article and Find Full Text PDF

Hyperelastic materials are extensively incorporated in medical implants and microelectromechanical systems due to their large, elastic, recoverable strains. However, their mechanical properties are sensitive to processing parameters that may lead to inconsistent characterization. Various test setups have been employed for characterizing hyperelastic materials; however, they are often costly.

View Article and Find Full Text PDF

Management of wind-turbine blade waste as high-content concrete addition: Mechanical performance evaluation and life cycle assessment.

J Environ Manage

January 2025

Department of Civil Engineering, Escuela Politécnica Superior, University of Burgos, c/ Villadiego s/n, 09001, Burgos, Spain. Electronic address:

The management of end-of-life wind-turbine blades in the coming years will be necessary, as a clear solution for their recycling is yet to be found due to their complex composition. The suitability of their mechanical recycling is therefore evaluated in this paper, obtaining Raw-Crushed Wind-Turbine Blade (RCWTB) for subsequent incorporation in high amounts of up to 10% vol. in concrete, replacing the aggregates to achieve Fiber-Reinforced Concrete (FRC).

View Article and Find Full Text PDF

Particle elasticity has widely been established to substantially influence immune cell clearance and circulation time of vascular-targeted carriers (VTCs). However, prior studies have primarily investigated interactions with macrophages, monocytic cell lines, and in vivo murine models. Interactions between particles and human neutrophils remain largely unexplored, although they represent a critical aspect of VTC performance.

View Article and Find Full Text PDF

Predicting Irida-Silicene: A Novel 2D Silicon Allotrope.

ACS Omega

December 2024

Faculty UnB Planaltina, Materials Science Postgraduate Program, University of Brasília, Brasília, Federal District 73345-010, Brazil.

Two-dimensional (2D) silicon-based materials have garnered significant attention for their promising properties, making them suitable for various advanced technological applications. Here, we present Irida-Silicene (ISi), a novel 2D silicon allotrope inspired by Irida-Graphene (IG), which was recently proposed and is entirely composed of carbon atoms. ISi exhibits a buckled structure composed of 3-6-8 membered rings, unlike its planar carbon counterpart.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!