Unlabelled: Acetabular reaming in minimally invasive surgery can be done using a newly designed minimally invasive reamer. The new minimally invasive reamer is narrower and chamfered, which results in two sharp edges. This design may result in acetabular cavities with less ideal spheres than those achieved with conventional reaming. We compared the acetabular shapes in nine pairs of cadaver acetabula. Minimally invasive reaming was performed in one acetabulum of each pair, and conventional reaming was performed on the contralateral side. A new digitizing technique, optical three-dimensional scanning, was applied to the reamed acetabula to determine the reamers' performance. Best-fit spheres were calculated for the reamed cavities, and all reamers were measured for exact dimensions. There were small deviations between the diameters of the reamer and the reamed cavity for the minimally invasive (mean, 0.1 mm; standard deviation, 0.5 mm) and conventional (mean, 0.3 mm; standard deviation, 0.4 mm) reamers. There were no significant differences between minimally invasive and conventional reaming. The mean differences between the reamer domes and the measured values showed a discrepancy of 2.2 mm (standard deviation, 0.08 mm) in the minimally invasive surgery group and 2.8 mm (standard deviation, 0.09 mm) in the conventional group. Although the acetabular reamer design has been modified, there were no significant differences in the acetabular shapes after minimally invasive or conventional reaming.

Level Of Evidence: Therapeutic Study, Level II (prospective comparative study with no statistically significant difference). See the Guidelines for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.blo.0000205902.13609.abDOI Listing

Publication Analysis

Top Keywords

minimally invasive
36
standard deviation
16
invasive surgery
12
conventional reaming
12
minimally
9
invasive
9
invasive reamer
8
acetabular shapes
8
reaming performed
8
invasive conventional
8

Similar Publications

Background: Robotic-assisted bariatric surgery is growing rapidly. The optimal approach to minimize complications remains unclear.

Objective: Assess robot utilization and compare 30-day outcomes for laparoscopic and robotic primary sleeve gastrectomy (SG) and Roux-en-Y gastric bypass (RYGB) using the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program (MBSAQIP) database.

View Article and Find Full Text PDF

Long-term outcomes of minimally invasive direct coronary artery bypass vs second generation drug eluting stent for management of isolated left anterior descending artery disease.

Int J Cardiol

December 2024

Department of Cardiac Surgery, Zbigniew Religa Heart Center "Medinet", Nowa Sol, Poland; Department of Cardiac Surgery and Interventional Cardiology, Faculty of Medicine and Medical Sciences, University of Zielona Gora, Zielona Gora, Poland.

Introduction: This study aimed to compare the long-term outcomes in a propensity matched population receiving either minimally invasive direct coronary artery bypass (MIDCAB) using left internal thoracic artery (LITA) to the left anterior descending artery (LAD) or percutaneous coronary intervention using second generation everolismus-eluting stents (DES-PCI) in patients treated for isolated proximal LAD stenosis.

Methods: Between January 2012 and December 2017, 421 patients with a nonemergency status undergoing primary isolated proximal LAD revascularization were retrospectively analyzed and were divided into two groups: 111 patients receiving MIDCAB LITA to LAD and 310 patients receiving DES-PCI. Propensity score matching selected 111 pairs and both groups were comparable for all baseline characteristics and well balanced.

View Article and Find Full Text PDF

Objective:  In recent years, the management of placenta accreta spectrum (PAS) has fallen into two categories: planned hysterectomy and conservative management to preserve fertility. However, optimal management remains unclear. Therefore, we conducted a systematic review and meta-analysis comparing the two to evaluate which approach was associated with lower surgical morbidity.

View Article and Find Full Text PDF

Background: Single port robotic platform offers articulation and 360° camera rotation for anorectal tumour excision in a narrow pelvic space. This study assesses the clinical usefulness and outcomes of SP robotic transanal surgery.

Methods: Nine patients who underwent transanal excision using the SP robotic platform were included.

View Article and Find Full Text PDF

An effective surgical educational system in the era of robotic surgery: "Double-Surgeon Technique" in robotic gastrectomy for minimally invasive surgery.

Langenbecks Arch Surg

December 2024

Department of Gastroenterological Surgery, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-Cho, Kita-Ku, Okayama City, Okayama, 700-8558, Japan.

Purpose: Gastric cancer (GC) remains a major malignancy. Robotic gastrectomy (RG) has gained popularity due to various advantages. Despite those advantages, many hospitals lack the necessary equipment for RG and are still performing laparoscopic gastrectomy (LG) due to its established minimal invasiveness and safety.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!