This study examined the effects of altering surface neuromuscular electrical stimulation (SNMES) parameters on the specific tension of the quadriceps femoris muscle. Seven able-bodied subjects had magnetic resonance images taken of both thighs prior to and immediately after four SNMES protocols to determine the activated muscle cross-sectional area (CSA). The four protocols were: (1) research (RES, 100 Hz, 450 micros, and amplitude set to evoke 75% of maximal voluntary isometric torque, MVIT); (2) pulse duration (PD, 100 Hz, 150 micros, same current as in RES); (3) frequency (FREQ, 25 Hz, 450 micros, and same current as in RES); (4) amplitude (AMP, 100 Hz, 450 mus, and current set to evoke the average of the initial torques of PD and FREQ, 45 +/- 9% of MVIT). Reducing the amplitude of the current from 75 to 45% of MVIT did not alter specific tension, 25 +/- 8 N/cm2, suggesting that the amplitude probably affects torque and the area of activated muscle proportionally. Shortening the pulse duration from 450 to 150 micros caused specific tension to drop from 25 +/- 6 to 20 +/- 6 N/cm2 (P < 0.05), indicating that pulse duration increased torque and the activated CSA disproportionally. Alternatively, reducing the frequency from 100 to 25 Hz decreased specific tension from 25 +/- 6 to 17 +/- 4 N/cm2 (P < 0.05), suggesting that the frequency increased torque without affecting the activated CSA. Clinicians who administer SNMES should be aware of the magnitude of adaptations to a given amplitude, pulse duration, and frequency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00421-006-0232-7 | DOI Listing |
Background: Anxiety and stress have been identified as potential risk factors of cognitive impairment, but research examining this association in midlife has been limited.
Method: The current study examined the associations between anxiety and stress symptoms, and cognition in middle-aged cognitively unimpaired adults (n = 2,463) enrolled in the Healthy Brain Project. Exploratory factor analysis was conducted on items in the Anxiety Subscale of the Hospital Anxiety and Depression Scale, Anxiety and Stress Subscales of the Depression, Anxiety and Stress Scale, and Perceived Stress Scale.
Sci Rep
January 2025
Department of Physical Chemistry, University of Tabriz, Tabriz, Iran.
Background: Yes-associated protein (YAP) is a crucial mechanosensor involved in mechanotransduction, but its role in regulating mechanical force-induced bone remodeling during orthodontic tooth movement (OTM) is unclear. This study aims to elucidate the relationship between mechanotransduction and mechanical force-induced alveolar bone remodeling during OTM.
Results: Our study confirms an asynchronous (temporal and spatial sequence) remodeling pattern of the alveolar bone under mechanical force during OTM.
Unfallchirurgie (Heidelb)
January 2025
Klinik für Orthopädie und Unfallchirurgie, MUM - Muskuloskelettales Universitätszentrum München, LMU Klinik, Marchioninistraße 15, 81377, München, Deutschland.
In the field of tension between generalists and specialists, in modern university trauma and orthopedic surgery the question arises as to which expertise has the greatest importance for the future of clinical care. University medicine consists of three large pillars: Research, teaching and treatment of patients. Each of these pillars is faced with the challenge of increasing specialization; however, generalists are extremely important for the future of university trauma surgery and orthopedics.
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
Qingdao Sunefire Science & Technology Shares Co., Ltd, Qingdao 266423, China.
Polymers are promising as stabilizers for developing eco-friendly foam extinguishing agents to solve the imminent pollution problem of fluorinated ones. Present work aims to elucidate the mechanisms by which polymers influence the performance of non-fluorinated foams. Specifically, it investigates the effects of three polymers-xanthan gum (XG), sodium carboxymethyl cellulose (CMCNa), and gelatin (GEL) on surface tension, conductivity, viscosity, foamability, foam stability, and rheology of the siloxane-based Gemini/sodium alpha-alkenyl sulfonate mixture.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!