Metabolic syndrome is associated with faster degeneration of bioprosthetic valves.

Circulation

Laval Hospital Research Center/Québec Heart Institute, Laval University, 2725 Chemin Sainte-Foy, Sainte-Foy, Québec, Canada, G1V-4G5.

Published: July 2006

AI Article Synopsis

  • Several studies indicate a connection between calcification of the aortic valve and atherosclerosis, with recent findings suggesting hypercholesterolemia may worsen degeneration of bioprosthetic valves.
  • In a study of 217 patients who received bioprosthetic valves, those with metabolic syndrome (MS) showed significantly faster deterioration in valve function, including greater increases in transprosthetic gradient and higher rates of regurgitation compared to those without MS.
  • The results suggest that MS is an independent risk factor for faster bioprosthetic valve degeneration, highlighting the potential for new medical therapies to mitigate structural deterioration of these valves.

Article Abstract

Background: Several studies have reported similarities between calcification of the native aortic valve and atherosclerosis. Recent studies also suggested that hypercholesterolemia may be a risk factor for calcific degeneration of bioprosthetic valves. The metabolic syndrome (MS) is associated with a higher risk of vascular atherosclerosis. We thus hypothesized that the atherogenic features of MS could accelerate bioprosthetic valve degeneration.

Methods And Results: We included 217 patients who underwent aortic valve replacement with a bioprosthetic valve in the study. Of these patients, 71 patients (33%) had MS defined according to the modified criteria proposed by the National Cholesterol Education Program Adult Treatment Panel III. The annualized increase in mean transprosthetic gradient and the worsening of transprosthetic regurgitation measured by Doppler echocardiography were used to assess the deterioration of valve hemodynamic function. Patients with MS had higher progression of gradient (+4+/-5 mm Hg/year versus +2+/-2 mm Hg/year, P<0.001), higher proportion of > or = 1/3 degree worsening of regurgitation (25% versus 12%, P=0.02), and higher proportion of valve function deterioration defined as regurgitation worsening and/or > or = 3 mm Hg/year increase in gradient (41% versus 25%, P=0.02) when compared with patients without MS. On multivariate analysis, MS was an independent predictor of gradient progression (P=0.01), regurgitation worsening (P=0.02), and valve function deterioration (P=0.02). The other independent predictors were diabetes, renal insufficiency, and higher mean gradient at baseline.

Conclusions: This is the first study to report that the MS is independently associated with faster bioprosthetic valve degeneration. This study could pave the way for the development of a new medical therapy able to significantly reduce the structural valve deterioration of bioprostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.105.000422DOI Listing

Publication Analysis

Top Keywords

bioprosthetic valve
12
valve
9
metabolic syndrome
8
syndrome associated
8
associated faster
8
degeneration bioprosthetic
8
bioprosthetic valves
8
aortic valve
8
valve function
8
function deterioration
8

Similar Publications

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF

Transcatheter Bailout: An Important Option During Complex Aortic Surgery.

Ann Thorac Surg Short Rep

December 2024

Division of Adult Cardiothoracic Surgery, Department of Surgery, University of California, San Francisco, San Francisco, California.

This report presents the case of a 66-year-old man with acute torrential aortic insufficiency after a Ross procedure 20 years earlier, a biologic aortic valve replacement 16 years earlier, and a transcatheter valve-in-valve 4 years earlier. He underwent third-time sternotomy, revealing that the pulmonary autograft was heavily calcified and frozen to the homograft. The previous transcatheter valve-in-valve was explanted.

View Article and Find Full Text PDF

Background: Continuous retrograde flow across the aortic valve from left ventricular assist device (LVAD) therapy can result in cusp damage and progressive aortic regurgitation, potentially triggering recurrent heart and multiorgan failure. The management of aortic regurgitation after LVAD implantation has not been well defined.

Methods: This study retrospectively reviewed the investigators' experience with the management of de novo aortic regurgitation requiring intervention in patients with continuous-flow LVAD.

View Article and Find Full Text PDF

Background: Comparative studies of outcomes between different biological mitral valve prostheses are scarce. This study compares the late clinical results of valve replacement with the Epic and Mosaic bioprostheses.

Methods: Patients undergoing isolated elective mitral valve replacement (MVR) between 2005 and 2019 were eligible for inclusion.

View Article and Find Full Text PDF

A 38-year-old woman underwent minimally invasive aortic valve replacement with a 21-mm Inspiris aortic valve and Cor-Knot for type 0 bicuspid valve and severe aortic stenosis. Postoperative transthoracic echocardiography was uneventful. Four months later, she experienced shortness of breath.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!