[Establishment of molecular differential diagnostic (MDD) technology for detection of common respiratory viruses].

Zhonghua Shi Yan He Lin Chuang Bing Du Xue Za Zhi

State Key Laboratory for Infectious Disease Prevention and Control, Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 100052, China.

Published: June 2006

Background: To provide rapid laboratory evidence for diagnosis of respiratory infection and help diagnose accurately and reduce the spread of disease, so that the patients can be diagnosed and treated early.

Methods: Thirteen kinds of respiratory viruses were detected by using Genaco's MDD technology.

Results: All the specimens were detected, the total positive rate was 100%; the sensitivity of the method was 10e2 (pfu/ml).

Conclusion: The MDD system can distinguish the 13 respiratory viruses, which helps diagnosis of respiratory viral infection.