Schlieren visualization of ultrasonic wave fields with high spatial resolution.

Ultrasonics

Institute of High Frequency Engineering, Ruhr-University Bochum, Building IC 6/132, D-44780 Bochum, Germany.

Published: December 2006

The visualization of ultrasonic wave fields in optically transparent liquids using the acousto-optic interaction is a well proven tool for the experimental investigation of wave propagation including wave field interaction effects with certain discontinuities and obstacles like reflection, refraction, and diffraction effects as well as for transducer testing and design. For high resolution visualization of wave fields including pulsed waveforms, pulsed light sources and sensitive optical imaging sensors with certain specifications are needed. In this paper the technical requirements of optical and electronic components for high resolution visualization of ultrasound wave fields will be presented. Also, specifications and operation results of a new designed, inexpensive Schlieren optical system will be presented, which is capable of pulsed wave field visualization in the MHz frequency range. The spatial resolution is high enough, not only for accurate beam shape and wave pattern visualization, but also for a gray-scaled display of wave amplitudes including amplitude zero crossings in ultrasound pulses. Consequently, ultrasonic wavelengths can be visualized quantitatively as well as wavelength changes of the ultrasound pulses while traveling through transparent media with different sound velocities. Results to be presented will include 2 MHz and 10 MHz experiments using single transducers as well as linear arrays of commercial medical scanners during their standard operation showing the system beamforming characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2006.05.209DOI Listing

Publication Analysis

Top Keywords

wave fields
16
resolution visualization
12
wave
9
visualization ultrasonic
8
ultrasonic wave
8
spatial resolution
8
wave field
8
high resolution
8
will presented
8
ultrasound pulses
8

Similar Publications

Near-Field Clutter Mitigation in Speckle Tracking Echocardiography.

Ultrasound Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:

Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

View Article and Find Full Text PDF

Introduction: Binge Eating Disorder (BED) has high lifetime prevalence rates, low treatment success rates, and high rates of treatment dissatisfaction, early discontinuation of care, and recurrence. Complementary and integrative health (CIH) interventions (non-mainstream practices used with conventional approaches for whole-person treatment) hold potential to overcome many treatment barriers and improve BED treatment outcomes. Some CIH interventions have empirical support for use in eating disorders.

View Article and Find Full Text PDF

Ultra-wide range control of topological acoustic waveguidesa).

J Acoust Soc Am

January 2025

Jianglu Mechanical Electrical Group Company Limited, Xiangtan 411105, China.

Topological acoustic waveguides have a potential for applications in the precise transmission of sound. Currently, there is more attention to multi-band in this field. However, achieving tunability of the operating band is also of great significance.

View Article and Find Full Text PDF

Purpose: To determine how Hardy-Rand-Rittler (HRR) colour vision testing correlates with visual functional and structural assessments in Cone and Cone-Rod Dystrophy.

Methods: Thirty-four Cone and 69 Cone-Rod Dystrophy patients diagnosed by electroretinography (ERG) at the Save Sight Institute in Sydney were included in a retrospective analysis. Each patient's HRR colour vision test scores were compared with markers of cone and rod system function including visual acuity (VA), ERG responses, changes on Spectral Domain Optical Coherence Tomography (OCT) and Fundus Autofluorescence.

View Article and Find Full Text PDF

Beam-divergence characteristics of single negative ion beamlet have been experimentally investigated with a superimposition of a controlled perturbation of a radio frequency wave (RF) field in a filament-arc discharge negative ion source. Oscillations of a negative-ion beamlet width and axis responding to the RF perturbation were observed, which may be a cause of the larger beam divergence angle of the RF negative ion source for ITER. It is pointed out that the oscillation of the beamlet width depends on the perveance and on an RF frequency such that the oscillation is suppressed at perveance-matched conditions and at low RF frequency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!