Endovascular repair in management of thoracic aortic aneurysms.

Int J Cardiovasc Imaging

Department of Cardiovascular Surgery, Gulhane Military Medical Academy, PK 56, 06552, Cankaya, Ankara, Turkey.

Published: February 2007

Objective: Aneurysms of the thoracic aorta are still potentially life-threatening situations. The conventional operation is still associated with morbidity. Endovascular stent graft repair offers an alternative to conventional operation for management of aortic diseases. Our aim was to report our experience with endovascular stent graft repair of thoracic aortic aneurysms.

Patients And Methods: Between November 2002 and October 2005, endovascular stent graft repair was performed in 26 patients: post-traumatic aortic aneurysm (n=4), Type B dissection (n=3) and descending thoracic aortic aneurysm (n=19). The deployed stent graft systems were Talent-Medtronic (n=14) and Excluder-Gore (n=12).

Results: Successful deployment of the stent grafts in the appropriate position was achieved in all patients. There was neither hospital mortality nor paraplegia. Late and non-procedure related death occurred in only one patient (3.8%). An average of 40% shrinkage of the aneurysmal space was observed. There was no early mortality and endoleaks. The median intensive care unit and hospital stay times were 1 and 7 days (range 4-13 days), respectively. Post-operative computed tomography scans were obtained in all patients and complete thrombosis was observed in the false lumen of dissecan aneurysms (n=3) and sac of saccular aneurysms in 25 patients. Mean follow up time was 17.1+/-5.4 months.

Conclusions: Endovascular stent graft treatment for treatment of thoracic aorta aneurysm, Type B dissection and traumatic disease of the thoracic aorta is technically feasible. Although the short and mid-term results are encouraging the long term results will determine the future of this treatment.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-006-9109-4DOI Listing

Publication Analysis

Top Keywords

stent graft
20
endovascular stent
16
thoracic aortic
12
thoracic aorta
12
graft repair
12
conventional operation
8
aortic aneurysm
8
type dissection
8
thoracic
6
stent
6

Similar Publications

Objective: Half of re-interventions after fenestrated and branched endovascular aortic repair (FB-EVAR) are target vessel related. Regarding bridging stent choice, existing data are controversial. This meta-analysis aimed to evaluate the performance of Advanta V12/iCAST as bridging stent in FB-EVAR.

View Article and Find Full Text PDF

Endoanchors for the distal fixation of iliac limb in endovascular aneurysm repair.

J Vasc Surg Cases Innov Tech

April 2025

Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.

This report details the case of an 84-year-old male with an infrarenal abdominal aortic aneurysm and a dilated right common iliac artery eligible for endovascular treatment. A bifurcated stent graft (Medtronic Endurant IIs) was used to treat the aneurysm. To address the concerns of instability of the right iliac limb, four endoanchors (Heli-FX EndoAnchor, Medtronic) were placed at the distal landing zone to provide additional fixation.

View Article and Find Full Text PDF

Stanford type B aortic dissection involving the left subclavian artery (LSA) poses significant clinical challenges. The Castor single-branch stent graft and in situ fenestration are commonly used techniques, but the better endovascular treatment remains debated. This study evaluates the clinical effects of the Castor single-branched stent graft versus in situ fenestration in treating Stanford type B aortic dissection involving the LSA.

View Article and Find Full Text PDF

Ascending-to-Descending Aortic Bypass of a Thoracic Stent Graft Infection with a Rare Pathogen.

Surg Infect (Larchmt)

January 2025

Division of Thoracic and Cardiovascular Surgery, Department of Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, Chang Gung University, Taoyuan City, Taiwan.

Stent graft infection (SGI) caused by complex is rare. The usage of ascending-to-descending aortic bypass (ADAB) in such situations has not yet been fully discussed. Case report and literature review.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!