To examine the effects of firefighting personal protective ensemble (PPE) and self-contained breathing apparatus (SCBA) on exercise performance, 12 males completed two randomly ordered, graded exercise treadmill tests (GXTPPE and GXTPT). Maximal oxygen consumption (VO2max) during GXTPPE was 17.3% lower than the GXTPT in regular exercise clothing (43.0 +/- 5.7 vs. 52.4 +/- 8.5 ml/kg per min, respectively). The lower VO2max during the PPE condition was significantly related (r = 0.81, p < 0.05) to attenuated peak ventilation (142.8 +/- 18.0 vs. 167.1 +/- 15.6 l/min), which was attributed to a significant reduction in tidal volume (2.6 +/- 10.4 vs. 3.2 +/- 0.4 l). Breathing frequency at peak exercise was unchanged (55 +/- 7 vs. 53 +/- 7 breaths/min). The results of this investigation demonstrate that PPE and the SCBA have a negative impact on VO2max. These factors must be considered when evaluating aerobic demands of fire suppression work and the fitness levels of firefighters.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00140130600667451DOI Listing

Publication Analysis

Top Keywords

self-contained breathing
8
breathing apparatus
8
maximal oxygen
8
+/-
8
effects self-contained
4
apparatus fire
4
fire protective
4
protective clothing
4
clothing maximal
4
oxygen uptake
4

Similar Publications

The role of personal protective equipment (PPE) in reducing firefighter exposure to chemical hazards: A systematic review.

J Occup Environ Hyg

November 2024

School of Public Health and Social Work, Faculty of Health, Queensland University of Technology, Kelvin Grove, Queensland, Australia.

This paper aims to investigate the effectiveness of personal protective equipment (PPE) in reducing firefighter exposure to various hazardous chemicals from the smoke emitted during fires. A systematic review of peer-reviewed articles was undertaken utilizing five databases: Medline, Embase, Web of Science, Scopus, and CINHAL. Studies published between 2013 and 2023 that investigated the effectiveness of PPE in reducing firsthand exposure to at least one chemical were included.

View Article and Find Full Text PDF
Article Synopsis
  • Self‑Contained Breathing Apparatus (SCBA) is vital for firefighter safety but often causes musculoskeletal issues and discomfort while in use.
  • A study tested a new SCBA design (SCBANovel) against a traditional pack (SCBATrad) with ten volunteer firefighters to measure muscle activity, pressure, and discomfort.
  • Results indicated that the SCBANovel pack significantly reduced muscle strain, shoulder and waist pressure, and lower back discomfort compared to the traditional SCBA.
View Article and Find Full Text PDF

Pushing Scuba to New Heights: Approach, Decompression, and Logistical Considerations for High-Altitude Diving.

High Alt Med Biol

October 2024

Departments of Anesthesiology and Medicine, Center for Hyperbaric Medicine & Environmental Physiology, Duke University, Durham, North Carolina, USA.

There is interest among technical, expedition, commercial, and military divers in expanding diving operations to high altitude. However, altitude diving presents unique challenges including acclimatization, increased decompression sickness (DCS) risk, and logistical and equipment considerations. Divers must plan altitude acclimatization strategies conservatively to reduce risk of acute mountain sickness and dehydration before diving.

View Article and Find Full Text PDF

Firefighters face a multitude of hazards in their line of duty, with overexertion being one of the foremost causes of injuries or fatalities. This high risk is often exacerbated by the burden of carrying a heavy self-contained breathing apparatus (SCBA). This study aims to explore the impact of SCBA weight on firefighters' musculoskeletal joint movements.

View Article and Find Full Text PDF

Understanding the complex three-dimensional (3D) dynamic interactions between self-contained breathing apparatus (SCBA) and the human torso is critical to assessing potential impacts on firefighter health and informing equipment design. This study employed a multi-inertial sensor fusion technology to quantify these interactions. Six volunteer firefighters performed walking and running experiments on a treadmill while wearing the SCBA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!