Objective: In aortic valve regurgitation and aortic dilatation, preservation of the aortic valve is possible by means of root remodeling (Yacoub procedure) or valve reimplantation (David procedure). In vivo studies suggest that reimplantation might substantially influence aortic valve-motion characteristics. Evaluation of aortic valve movement in vivo, however, is technically limited and is difficult to standardize. We evaluated the aortic valve-motion pattern echocardiographically in vitro after reimplantation and remodeling.

Methods: By using aortic roots of house pigs (aortoventricular diameter, 22 mm) a Yacoub procedure (22-mm graft; group Y, n = 5) or a David I procedure (24-mm graft; group D, n = 5) was performed. Roots after supracommissural replacement (22-mm graft; group C, n = 5) served as control valves. In an electrohydraulic, computer-controlled pulse duplicator the valves were tested at flows of 2, 4, 7, and 9 L/min. Echocardiographically assessed parameters were rapid valve-opening velocity, slow valve-closing velocity, rapid valve-closing velocity, rapid valve-opening time, rapid valve-closing time, ejection time, maximum valve opening, slow valve-closing displacement, and maximum flow velocity.

Results: Mean rapid valve-opening velocity and mean rapid valve-closing velocity at a cardiac output of 2 to 9 L/min were fastest in group D (rapid valve-opening velocity: 69 +/- 10 cm/s [group D] vs 39 +/- 4 cm/s [group Y] vs 42 +/- 4 cm/s [group C], P = .0041; rapid valve-closing velocity: 22 +/- 2 cm/s [group D] vs 16 +/- 2 cm/s [group Y] vs 17 +/- 1 cm/s [group C], P = .0272), and slow valve-closing velocity was slowest in group D (0.2 +/- 0.1 cm/s [group D] vs 1.0 +/- 0.3 cm/s [group Y] vs 0.6 +/- 0.1 cm/s [group C], P = .0063). With increasing cardiac output, the difference in rapid valve-opening velocity between the groups increased, the difference in slow valve-closing velocity remained unchanged, and the difference in rapid valve-closing velocity decreased.

Conclusions: In this standardized experimental setting remodeling of the aortic valve provides significantly smoother valve movements. This might contribute to preservation of a better valve performance during long-term follow-up.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2006.02.034DOI Listing

Publication Analysis

Top Keywords

+/- cm/s
36
cm/s [group
36
valve-closing velocity
28
[group +/-
24
aortic valve
20
rapid valve-opening
20
rapid valve-closing
20
valve-opening velocity
16
slow valve-closing
16
graft group
12

Similar Publications

Effects of Melatonin Administration on Physical Performance and Biochemical Responses Following Exhaustive Treadmill Exercise.

Curr Issues Mol Biol

November 2024

Faculty of Health Sciences, Universidad San Jorge, Autov. A-23 Zaragoza-Huesca Km. 299, 50830 Villanueva de Gállego, Zaragoza, Spain.

Exercise, despite being a beneficial activity for health, can also be a source of oxidative imbalance, which can lead to a decrease in performance. Furthermore, melatonin is an endogenous molecule that may counteract exercise-induced oxidative stress. The aim of this study was to evaluate the potential ergogenic and antioxidant capacity of melatonin administered for a maximal effort test.

View Article and Find Full Text PDF

Objective: This study aimed to longitudinally investigate the association between circulating neutrophil count and the progression of arterial stiffness and to ascertain whether resting heart rate (RHR) mediates this association.

Methods: The current study included 56,760 participants with brachial-ankle pulse wave velocity (baPWV) measurements from a real-life, prospective cohort in China. The associations of circulating neutrophil (exposure) with baseline baPWV, baPWV progression, and arterial stiffness (outcomes), as well as RHR (mediator) were assessed using multivariable linear and Cox regression models and mediation analysis.

View Article and Find Full Text PDF

Dynamic resistance exercise (RE) produces sinusoidal fluctuations in blood pressure, with hypotension and cerebral hypoperfusion commonly observed immediately following RE. Whether the cerebral vasculature adapts to these regular blood pressure challenges is unclear. This study examined the cerebrovascular response to post-dynamic RE orthostasis.

View Article and Find Full Text PDF

Background: For the development and validation of dynamic treatment modalities and processes on the MR-linac, independent measurements should be performed that validate dose delivery and linac behavior at a high temporal resolution. To achieve this, a detector with both high temporal and spatial resolution is necessary.

Purpose: This study investigates the suitability of a Delta4 Phantom+ MR (Delta4) detector array for time-resolved dosimetry in the 1.

View Article and Find Full Text PDF

This study aims to evaluate cerebrospinal fluid (CSF) flow dynamics within ventricles, and the subarachnoid space (SAS) using the velocity selective spin labeling (VSSL) MRI method with Fourier-transform-based velocity selective inversion preparation. The study included healthy volunteers who underwent MRI scanning with specific VSSL parameters optimized for CSF flow quantification. The VSSL sequence was calibrated against phase-contrast MRI (PC-MRI) to ensure accurate flow velocity measurements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!