A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative, radio-guided sentinel lymph node mapping in 110 nonsmall cell lung cancer patients. | LitMetric

Background: Sentinel lymph node identification has been tested in lung cancer patients with conflicting results. The present study was designed to assess the sensitivity, negative predictive value, and accuracy of intraoperative sentinel lymph node mapping by means of a radio-guided method in patients with nonsmall cell lung cancer to find the most appropriate definition of sentinel lymph node and to evaluate the usefulness of different particle sizes of radiocolloid.

Methods: One hundred ten patients with clinically N0 nonsmall cell lung cancer were enrolled in the pilot study of intraoperative sentinel node identification. Four quadrants of the peritumoral tissue were injected with 2 mL of 0.5 mCi technetium-99m suspension. Four radiocolloids of different particle size were used. After complete lymphadenectomy, all resected lymph nodes were examined with hematoxylin-eosin staining. All sentinel nodes negative for metastases by routine staining were searched further for metastatic deposits with both serial sections and immunohistochemistry for cytokeratins.

Results: The radio-guided method had a high identification rate, a high sensitivity, and a high negative predictive value (100%, 87%, and 93%, respectively) when immunohistochemistry was considered. When standard hematoxylin and eosin staining was applied, sensitivity and negative predictive value of sentinel lymph node labeling was lower (74% and 89%, respectively). No significant differences were found in either the sensitivity or negative predictive value among the colloid solutions of different particle size used in radio labeling, although smaller particles have shown a tendency to produce better results.

Conclusions: The radio-guided technique provides efficient sentinel lymph node identification in lung cancer. Further studies are warranted to confirm the clinical utility of this strategy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2006.01.094DOI Listing

Publication Analysis

Top Keywords

sentinel lymph
24
lymph node
24
lung cancer
20
negative predictive
16
nonsmall cell
12
cell lung
12
node identification
12
sensitivity negative
12
sentinel
8
node mapping
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!