A technique for assessing the immediate and prolonged efficacy of surgical scrubs and alcoholic hand rubs is described. A mean baseline count is obtained from all volunteers and logarithmic reductions in resident skin flora immediately after one or more applications, and after wearing gloves for 3 h, are measured. Loose-fitting surgical gloves are used for sampling resident flora. Preparations were applied using a standard technique for 2 min, apart from one test with 70% isopropanol (IPA) in which the application time was 30 s. Two studies are described, one of which compared four chlorhexidine scrubs, and the second 70% IPA, 7.5% povidone-iodine scrub, 2% triclosan cleanser and unmedicated bar soap. In spite of their constituent similarity, the four chlorhexidine scrubs varied considerably in efficacy and user acceptability. A 2 min application of 70% IPA was the most effective treatment, and gave log10 reductions of 1.65 for immediate and 1.58 for prolonged effect. This was marginally more effective than a 30 s application, but the difference was not significant. 'Hibiscrub' was the most effective aqueous formulation and gave reductions of 1.01 for immediate effect and 1.16 for prolonged effect. The test described could be used by reference centres and manufacturers to assess the efficacy of new and existing surgical hand disinfection formulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/0195-6701(91)90262-7 | DOI Listing |
Objectives: Bennett's fracture, the most common intra-articular fracture occurring at the base of the thumb, accounts for less than 1% of all hand fractures. It typically results from specific traumatic mechanisms, deforming forces, and ligamentous injuries. To compare the functional outcomes and sequelae in patients with Bennett's fracture treated surgically using: Open reduction and internal screw fixation, closed reduction and percutaneous fixation, arthroscopy-assisted reduction and screw fixation.
View Article and Find Full Text PDFInt J Control Autom Syst
September 2024
Biomedical Engineering Department, Rowan University, Glassboro, NJ 08028, USA.
In the face of challenges encountered during femur fracture surgery, such as the high rates of malalignment and X-ray exposure to operating personnel, robot-assisted surgery has emerged as an alternative to conventional state-of-the-art surgical methods. This paper introduces the development of a leader-follower robot-assisted system for femur fracture surgery, called Robossis. Robossis comprises a 7-DOF haptic controller and a 6-DOF surgical robot.
View Article and Find Full Text PDFBMJ Oncol
March 2024
Institute for Global Health, University College London, London, UK.
The Iraqi population has lived under four decades of conflicts, warfare and political instability. The health consequences of the protracted conflict continue to persist. This work critically analyses Iraq's barriers to delivering and accessing cancer care during the conflicts that Iraq passed through from 1980 to 2017.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Background: Olecranon fractures account for 8 ∼ 10% of all elbow fractures and usually require surgical intervention. Tension band wiring (TBW) is considered as the standard treatment while it is associated with high re-operation rates.
Objective: This study aims to compare the functional outcomes, complications and re-operations of hook plate fixation (HPF) versus TBW in treating Mayo Type II olecranon fractures.
Sci Rep
January 2025
Department of Orthopaedic Surgery, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582, Japan.
While silk fibroin (SF) obtained from silkworm cocoons is expected to become a next-generation natural polymer, a fabrication method for SF-based artificial nerve conduits (SFCs) has not yet been established. Here, we report a bioresorbable SFC, fabricated using a novel freeze-thaw process, which ensures biosafety by avoiding any harmful chemical additives. The SFC demonstrated favorable biocompatibility (high hydrophilicity and porosity with a water content of > 90%), structural stability (stiffness, toughness, and elasticity), and biodegradability, making it an ideal candidate for nerve regeneration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!