A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Variability of repeated coronary artery calcium measurements on low-dose ECG-gated 16-MDCT. | LitMetric

Objective: High reproducibility on coronary artery calcium (CAC) scoring is a key requirement in monitoring the progression of coronary atherosclerosis. Retrospective ECG-gated helical CT has been shown to be superior to prospective gating helical CT in the reproducibility of CAC measurements. However, it brings with it a high level of radiation exposure. The purpose of this study was to compare low- and standard-dose protocols in the variability of CAC scores and in image quality, thereby assessing the feasibility of low-dose retrospective ECG-gated helical CT in CAC measurements.

Subjects And Methods: Eighty-six patients with CAC were scanned using a tube current setting of 100 mA once and then a tube current setting equivalent to the patient's body weight twice. CAC scores (Agatston and volume) and interscan variability were evaluated. The mean and SD of the CT attenuation values in regions of interest in the aorta were measured, and the value (mean + 2 x SD) was obtained.

Results: A high correlation of log(10) (Agatston score + 1) was observed between sequential helical CT scans (r = 0.998). The variability in CAC measurements ranged from 11% to 12% for both the Agatston and volume scores. With the tube current equivalent to body weight, the value (mean + 2 x SD) did not exceed a CT attenuation value of 130 H.

Conclusion: Low-dose retrospective ECG-gated helical CT-yielding low variability and achieving the level of image quality needed to measure CAC-can be used to monitor patients with coronary atherosclerosis.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.05.0052DOI Listing

Publication Analysis

Top Keywords

retrospective ecg-gated
12
ecg-gated helical
12
tube current
12
coronary artery
8
artery calcium
8
coronary atherosclerosis
8
cac measurements
8
variability cac
8
cac scores
8
image quality
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!