Previously, the association between urinary cadmium (Cd) concentration and indicators of renal dysfunction, including beta(2)-microglobulin (beta(2)-MG), total protein and N-acetyl-beta-D-glucosaminidase (NAG) were investigated in 1270 inhabitants > or = 50 years of age (547 men, 723 women) in a Cd non-polluted area in Japan and showed that a dose-response relationship existed between renal effects and Cd exposure in the general environment without any known Cd pollution. However, the threshold levels of urinary Cd could not be estimated at that time. In the present study, the threshold levels of urinary Cd were estimated as the benchmark dose low (BMDL) using the benchmark dose (BMD) approach. Urinary Cd excretion was divided into 6-7 categories, and an abnormality rate was calculated for each. Cut-off values for urinary substances were defined as corresponding to the 84% upper limit values, which were calculated from 2034 persons who had been living in the non-polluted areas and did not smoke. Then the BMD and BMDL were calculated using a log-logistic model. The values of BMD and BMDL for all urinary substances could be calculated. The BMDL for the 84% cut-off value of beta(2)-MG, setting an abnormal value at 5%, was 2.0 microg g(-1) creatinine (cr) in men and 1.6 microg g(-1) cr in women. In conclusion, the present study demonstrated that the threshold level of urinary Cd could be estimated in people living in the general environment without any known Cd-pollution in Japan, and the value was inferred to be almost the same as that in Belgium and Sweden.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jat.1147DOI Listing

Publication Analysis

Top Keywords

benchmark dose
12
urinary estimated
12
renal dysfunction
8
non-polluted area
8
area japan
8
general environment
8
threshold levels
8
levels urinary
8
urinary substances
8
bmd bmdl
8

Similar Publications

Background: Bone scans using technetium-99m methylene diphosphonate (99mTc-MDP) are widely used in nuclear medicine for diagnosing various bone disorders. However, the radiation exposure associated with these procedures necessitates careful consideration and optimization.

Aim: This study aimed to evaluate radiation doses in terms of Effective Dose (ED) and establish Diagnostic Reference Levels (DRLs) for 99mTc-MDP bone scans in Saudi Arabia.

View Article and Find Full Text PDF

Proton minibeam radiation therapy (pMBRT) dose profile is characterized by highly heterogeneous dose in the plane perpendicular to the beam direction and rapidly changing depth dose profiles. Typically, dose measurements are benchmarked against in-house Monte Carlo simulation tools. It is essential to have a treatment planning system (TPS) that can accurately predict pMBRT doses in tissue and be available via commercial platform for preclinical and clinical use.

View Article and Find Full Text PDF

Positron emission tomography (PET) imaging plays a pivotal role in oncology for the early detection of metastatic tumors and response to therapy assessment due to its high sensitivity compared to anatomical imaging modalities. The balance between image quality and radiation exposure is critical, as reducing the administered dose results in a lower signal-to-noise ratio (SNR) and information loss, which may significantly affect clinical diagnosis. Deep learning (DL) algorithms have recently made significant progress in low-dose (LD) PET reconstruction.

View Article and Find Full Text PDF

Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).

Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.

View Article and Find Full Text PDF

The MC-LR induced neuroinflammation and the disorders of neurotransmitter system in zebrafish (Danio rerio): Oxidative stress as a key.

Fish Shellfish Immunol

January 2025

College of Fisheries, Huazhong Agricultural University, Wuhan 430070, China; Engineering Research Center of Green Development for Conventional Aquatic Biological Industry in the Yangtze River Economic Belt, Ministry of Education, Wuhan, 430070, China; Hubei Provincial Engineering Laboratory for Pond Aquaculture, Wuhan, 430070, China; Freshwater Aquaculture Collaborative Innovation Center of Hubei Province, Wuhan, 430070, China. Electronic address:

Microcystin-leucine-arginine (MC-LR) has been shown to induce neuroinflammation and disrupt neurotransmitter system. However, little is known about the mechanism of toxicity. In this study, male adult zebrafish (Danio rerio) were exposed to MC-LR at concentrations of 0, 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!