A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)-methanol-tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 micrograms/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is less than 6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 micrograms/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0378-4347(91)80417-bDOI Listing

Publication Analysis

Top Keywords

cetirizine human
8
human urine
8
high-performance liquid
8
micrograms/ml urine
8
urine
5
determination cetirizine
4
urine high-performance
4
liquid chromatography
4
chromatography high-performance
4
liquid chromatographic
4

Similar Publications

Probing the Histamine H Receptor Binding Site to Explore Ligand Binding Kinetics.

J Med Chem

January 2025

Amsterdam Institute of Molecular and Life Sciences (AIMMS), Division of Medicinal Chemistry, Faculty of Science, Vrije Universiteit Amsterdam, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands.

Analysis of structure-kinetic relationships (SKR) can contribute to an improved understanding of receptor-ligand interactions. Here, fragment (4-(2-benzylphenoxy)-1-methylpiperidine) was used in different fragment growing approaches to mimic the putative binding mode of the long residence time (RT) ligands olopatadine, acrivastine, and levocetirizine at the histamine H receptor (HR). SKR analyses reveal that introduction of a carboxylic acid moiety can increase RT at HR up to 11-fold.

View Article and Find Full Text PDF

Data mining in FAERS: association of newer-generation H1-antihistamines with nervous system disorders.

BMC Pharmacol Toxicol

December 2024

Department of Pharmacy, West China Second University Hospital, Sichuan University, Chengdu, Sichuan, 610041, China.

Background: H1-antihistamines are widely used to treat symptoms depending on histamine release in a variety of conditions. However, neurological adverse events have been reported in post-marketing surveillance studies and there are limited literatures comparing the neurological disorders associated with newer-generation H1-antihistamines from real-world datasets.

Aims: We performed a comparative analysis of nervous system disorders and several newer-generation H1-antihistamines including: cetirizine, loratadine, levocetirizine, desloratadine and fexofenadine.

View Article and Find Full Text PDF

ICOSLG Is Associated with Anti-PD-1 and Concomitant Antihistamine Treatment Response in Advanced Melanoma.

Int J Mol Sci

November 2024

Melanoma, Cancer Immunotherapy and Development Therapeutics Unit, Istituto Nazionale Tumori IRCCS "Fondazione G. Pascale", Via Mariano Semmola, 53, 80131 Naples, Italy.

We previously demonstrated that patients with metastatic unresectable stage IIIb-IV melanoma receiving cetirizine (a second-generation H1 antagonist antihistamine) premedication with immunotherapy had better outcomes than those not receiving cetirizine. In this retrospective study, we searched for a gene signature potentially predictive of the response to the addition of cetirizine to checkpoint inhibition (nivolumab or pembrolizumab with or without previous ipilimumab). Transcriptomic analysis showed that inducible T cell costimulator ligand (ICOSLG) expression directly correlated with the disease control rate (DCR) when detected with a loading value > 0.

View Article and Find Full Text PDF

In this research study, a simple, rapid, sensitive, and cost-effective Reverse Phase High Performance Liquid Chromatography method was developed and validated for determination of Cetirizine and Levocetirizine in human plasma. The drugs were separated on an ACE Generix100-5 C18 RP (250 × 4.6 mm, 5 μm) column, using Acetonitrile and Distilled water pH 7 (59:41 v/v) as mobile phase with a flow rate of 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!