A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Chronic performance of polyurethane catheters covalently coated with ATH complex: a rabbit jugular vein model. | LitMetric

Covalent complexes of antithrombin (AT) and heparin (ATH) have superb anticoagulant activity towards thrombin and factor Xa. Stability of polyurethane central venous catheters covalently modified with radiolabeled ATH was studied using a roller pump with saline or protease P-5147. Saline wash removed loosely bound ATH molecules to decrease graft density from 26 to 12 pmol/cm2. However, only slightly more ATH was removed by strong protease (from 12 to 7 pmol/cm2). To evaluate ATH-coated, heparin-coated, and uncoated catheters, a chronic rabbit jugular vein model was developed with catheters maintained for up to 30-106 days. Lumen occlusion was tested by drawing blood twice daily. Although unmodified or heparin-coated catheters occluded within 5-7 days after insertion, all ATH catheters remained patent throughout the experiment. Scanning electron microscopy (SEM) analysis of heparin and uncoated catheters revealed extensive thrombosis (lumen+mural) while ATH catheters were unaffected. Visual observation showed significant deposition of protein and cells on control and heparin-modified catheters and, to a lesser degree, on ATH-coated surfaces. SEM showed no fibrin inside or outside of ATH catheters, which remained patent in extended studies out to 106 days. Although atomic force microscopy showed ATH coatings to be rough, 6-fold higher anti-factor Xa activity likely contributed to increased patency. Our data confirm that ATH-modified catheters are stable and have superior potency compared to heparin or control catheters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.biomaterials.2006.05.005DOI Listing

Publication Analysis

Top Keywords

catheters
12
ath catheters
12
ath
9
catheters covalently
8
rabbit jugular
8
jugular vein
8
vein model
8
uncoated catheters
8
catheters remained
8
remained patent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!