Background: The automatic, threshold tracking, pacing algorithm developed by St. Jude Medical, verifies ventricular capture beat by beat by recognizing the evoked response following each pacemaker stimulus. This function was assumed to be not only energy saving but safe. This study estimated the extension in longevity obtained by AutoCapture (AC) compared with pacemakers programmed to manually optimized, nominal output.
Methods: Thirty-four patients who received the St. Jude Affinity series pacemaker were included in the study. The following measurements were taken: stimulation and sensing threshold, impedance of leads, evoked response and polarization signals by 3501 programmer during followup, battery current and battery impedance under different conditions. For longevity comparison, ventricular output was programmed under three different conditions: (1) AC on; (2) AC off with nominal output, and (3) AC off with pacing output set at twice the pacing threshold with a minimum of 2.0 V. Patients were divided into two groups: chronic threshold is higher or lower than 1 V. The efficacy of AC was evaluated.
Results: Current drain in the AC on group, AC off with optimized programming or nominal output was (14.33 +/- 2.84) mA, (16.74 +/- 2.75) mA and (18.4 +/- 2.44) mA, respectively (AC on or AC off with optimized programming vs. nominal output, P < 0.01). Estimated longevity was significantly extended by AC on when compared with nominal setting [(103 +/- 27) months, (80 +/- 24) months, P < 0.01). Furthermore, compared with the optimized programming, AC extends the longevity when the pacing threshold is higher than 1 V.
Conclusion: AC could significantly prolong pacemaker longevity; especially in the patient with high pacing threshold.
Download full-text PDF |
Source |
---|
ISA Trans
December 2024
College of Information Science and Engineering, Huaqiao University, Xiamen, 361002, China. Electronic address:
Iterative learning control (ILC) is a well-established method for achieving precise tracking in repetitive tasks. However, most ILC algorithms rely on a nominal plant model, making them susceptible to model mismatches. This paper introduces a novel normalization concept, developed from a frequency-domain perspective using a data-driven approach, thus eliminating the need for system model information.
View Article and Find Full Text PDFRes Involv Engagem
December 2024
HEARTS Study Team, Mental Health Accessibility and Policy Solutions Lab, Mississauga, Ontario, Canada.
Background: This commentary article critically assesses the inclusion and recognition of young adults with lived and living experiences (YALLE) in academic publishing. Stemming from our involvement in a health research study, this analysis interrogates the disparity between the stated importance of YALLE contributions in health research and their actual recognition, specifically in academic publications, which serve as the principal "currency" in research. This tokenism limits the potential for their unique insights to substantially enrich the discourse and dissemination of knowledge.
View Article and Find Full Text PDFElife
November 2024
Department of Neuroscience, University of Texas-Austin, Austin, United States.
In congenital stationary night blindness, type 2 (CSNB2)-a disorder involving the Ca1.4 (L-type) Ca channel-visual impairment is mild considering that Ca1.4 mediates synaptic release from rod and cone photoreceptors.
View Article and Find Full Text PDFISA Trans
December 2024
Center of Ultra-precision Optoelectronic Instrument Engineering, Harbin Institute of Technology, Harbin 150080, China; Key Lab of Ultra-precision Intelligent Instrumentation (Harbin Institute of Technology), Ministry of Industry and Information Technology, Harbin 150080, China; Department of Control Science and Engineering, Harbin Institute of Technology, Harbin 150080, China. Electronic address:
Control decoupling is the basic control step for precision MIMO (Multi-Input-Multi-Output) motion systems. After decoupling, the MIMO logical controlled plant can be diagonal dominant so that the control design for each DOF (Degree of Freedom) can be separately treated. However, due to the manufacturing tolerances and the assembling errors, the actual CoG (Center of Gravity) and actuator positions are inconsistent with the designed values.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!