A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MR imaging-guided breast localization system with medial or lateral access. | LitMetric

Purpose: To evaluate the degree of error of the authors' magnetic resonance (MR) imaging-guided needle localization system for biopsy of suspicious lesions visualized only with MR imaging, by using both prospectively recorded and retrospectively reviewed data, including MR imaging lesion coordinates as the reference standard, and to determine whether any lesion or breast characteristics affect this error.

Materials And Methods: Institutional review board approval, along with informed consent, was obtained as directed by the board. In 31 patients (age range, 34-64 years; mean age, 54.5 years), 38 wires were placed for 35 lesions by means of an MR-guided needle localization system with medial or lateral access and computer software assistance for needle placement calculation. Needle and wire placement error measurements were calculated before and after necessary placement correction, accounting for tissue shift in the z plane. The error was statistically correlated with MR imaging lesion variables, breast density, and histopathologic findings by means of univariate and multivariate linear regression analyses or two-tailed paired t test. Procedure times and the frequency of medial or lateral approaches were recorded.

Results: Eleven of 35 localizations (31%) were medial, and 24 of 35 (69%) were lateral. The mean total magnet time was 61.6 minutes, and the mean needle deployment time was 9 minutes (range, 4-17 minutes). Sixteen of 35 lesions (46%) were malignant (seven ductal carcinoma in situ, six invasive ductal, two invasive lobular, and one lymphoma). The mean uncorrected needle placement error was 1.3 mm (range, 0-6 mm) for the x plane, 2.4 mm (range, 0-6.5 mm) for the y plane, and 5.6 mm (range, 0-15.6 mm) for the z plane. Fourteen of 38 needles (37%) required repositioning for z-plane error. The corrected z-plane error improved to 3.2 mm (range, 0-10.0 mm). Factors that significantly increased the uncorrected error included tissue shift in the z plane (R = 0.7), small lesion size (R = -0.59), and fatty breast density (P = .029).

Conclusion: The authors' system is accurate for performing MR-guided needle localizations for both medial and lateral approaches. Factors that increased the uncorrected needle placement error included small lesion size, fatty breast density, and tissue shift in the z plane.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.2401041368DOI Listing

Publication Analysis

Top Keywords

medial lateral
16
localization system
12
needle placement
12
placement error
12
tissue shift
12
shift plane
12
breast density
12
system medial
8
lateral access
8
error
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!