Purpose: To evaluate factors influencing good and poor outcomes after intracorneal ring segment implantation to correct keratoconus.
Setting: Instituto Oftalmológico de Alicante (Vissum Corporation), University of Miguel Hernandez, Alicante, Spain.
Methods: A retrospective comparative study of the visual outcome, 25 eyes of 21 patients were implanted after intracorneal ring segments (Intacs, Addition Technology) as a method to correct keratoconus. Outcomes were evaluated 6 months after implantation based on the visual results. Group A comprised 20 eyes that gained 3 lines or more of best spectacle-corrected visual acuity (BSCVA) to correct keratoconus, and Group B comprised 5 eyes that lost 1 line of BSCVA.
Results: In Group A, the preoperative mean BSCVA was 0.43 (20/50) and the postoperative mean BSCVA, 0.82 (20/20) (P< or =.0001). In Group B, the preoperative mean BSCVA was 0.36 (20/63) and the postoperative mean BSCVA, 0.24 (20/80) (P< or =.02). The preoperative mean sphere power was 3.90 diopters (D) greater in Group B than in Group A (P< or =.007); the mean spherical equivalent was 4.36 D greater (P< or =.007), and the mean K-reading was 6.91 D greater (P< or =.001). The postoperative reduction in spherical dioptric power was 2.11 D (P< or =.027) and the mean spherical equivalent, 2.81 D (P< or =.003), significant only in Group A. The reduction in mean central K-readings was 4.30 D (P< or =.0001) in Group A and 6.19 D (P< or =.014) in Group B. The correlation of the preoperative mean K value to the postoperative BSCVA was significant at the .01 level by the Pearson test (-0.67). In Group A, all eyes (100%) had a mean K-reading < or =53 D. In Group B, 4 eyes (80%) had a mean K-reading > or =55 D.
Conclusion: Intacs provided better results in visual acuity and corneal topography quality and significantly reduced the spherical equivalent in eyes with keratoconus with relatively low mean K values (< or =53 D) and a relatively low spherical equivalent. In advanced keratoconus (mean K-reading > or =55 D), poor results can be anticipated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcrs.2006.02.012 | DOI Listing |
Clin Ophthalmol
December 2024
The Department of Ophthalmology, The Shammas Eye Medical Center, Lynwood, CA, USA.
Purpose: To evaluate the clinical outcomes of a new FDA approved toric aspheric hydrophobic acrylic intraocular lens.
Patients And Methods: This is a single surgeon, single-arm, on-label, non-randomized, prospective observational study. Thirty patients underwent bilateral cataract surgery (60 eyes) with placement of a Clareon™ Toric IOL in each eye.
Sci Rep
January 2025
Department of Ophthalmology, Medical Faculty, University Hospital Düsseldorf, Heinrich Heine University, Moorenstraße 5, 40225, Dusseldorf, Germany.
To assess the efficacy, safety, and stability of refractive outcomes in hyperopic Laser-Assisted in Situ Keratomileusis (LASIK) with and without the application of Mitomycin C (MMC). This randomized, parallel group, controlled multicenter trial included 140 hyperopic eyes. The participants were randomly assigned to two groups: one receiving LASIK with mitomycin C (MMC) (n = 70) and the other receiving LASIK without MMC (n = 70).
View Article and Find Full Text PDFFront Med (Lausanne)
December 2024
Chongqing Key Laboratory of Prevention and Treatment on Major Blinding Diseases, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Background: This study aimed to comprehensively explore the thickness and topographic distributions of retinal vessel alterations of different myopic eyes by using swept-source OCT angiography (SS-OCTA).
Methods: One hundred myopes were included in this observational cross-sectional study. All participants underwent a series of ocular examinations of biometrical parameters, including spherical equivalent refraction (SER), axial length (AL), intraocular pressure (IOP), curvature radius (CR), and others.
Clin Ophthalmol
December 2024
Département de Recherche Clinique, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.
Purpose: To evaluate clinical outcomes obtained after cataract surgery involving the implantation of a trifocal hydrophobic intraocular lens (IOL) and to determine if pupil size and the corneal aberrometric profile correlate to visual acuity at different distances.
Methods: 49 patients (98 eyes) underwent bilateral cataract surgery with the placement of FineVision HP IOLs for presbyopia and were assessed at 1- and 3- to 6-months post-surgery. Postoperatively, refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA) and the binocular defocus curve were measured.
Clin Exp Ophthalmol
January 2025
Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.
Background: To evaluate the 6-year physiological rates-of-change in ganglion cell inner plexiform layer (GCIPL) and retinal nerve fibre layer (RNFL) thickness measured with optical coherence tomography.
Methods: We included 2202 out of 2661 subjects from the population-based Singapore Chinese Eye Study who returned for follow-up 6 years after baseline examination (follow-up rate 87.7%).