A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The Thoratec Implantable Ventricular Assist Device (IVAD): initial clinical experience. | LitMetric

Background: The Thoratec Implantable Ventricular Assist Device (IVAD) is the only FDA-approved intracorporeal biventricular cardiac assist device. It is a titanium-coated version of its predecessor, the Paracorporeal Ventricular Assist Device (PVAD). The blood pump is compatible with the portable TLC-II driver, making home discharge feasible.

Methods: Nine consecutive patients were implanted with the IVAD from June 2005 through March 2006. The indications for support were acute heart failure in 6 cases and chronic heart failure in 3 cases. All patients were managed with maximal medical therapies including intravenous inotropic drugs prior to implant.

Results: All patients survived the surgical implant. Six patients were considered successful: 3 patients discharged to home and subsequently received transplantation, 2 are awaiting transplantation (1 at home and 1 in-house), and 1 patient was successfully explanted. Three patients expired postoperatively because of multiple organ system failure (2 patients) and pulmonary hemorrhage (1 patient). There were no device malfunctions. There was 1 localized driveline site infection and 1 thromboembolic event with partial visual loss.

Conclusions: The IVAD is a unique device capable of providing uni- or bi-ventricular support for either acute or chronic heart failure conditions. Its versatility permits bridge to transplant or recovery options. Home discharge is feasible.

Download full-text PDF

Source
http://dx.doi.org/10.1532/HSF98.20061028DOI Listing

Publication Analysis

Top Keywords

assist device
16
ventricular assist
12
heart failure
12
thoratec implantable
8
implantable ventricular
8
device ivad
8
support acute
8
failure cases
8
chronic heart
8
patients
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!