Background: Recently accumulated evidence has demonstrated that bright-light therapy in combination with antidepressants is effective in patients with non-seasonal major depression. Whether bright light has a sustained effect after discontinuation is, however, poorly investigated.

Method: In this double-blind randomized study we report the results from a 4-week follow-up period in patients with major non-seasonal depression who had been treated for 5 weeks with sertraline combined with bright-light therapy or sertraline combined with dim-light therapy. At the beginning of the follow-up period the light therapy was stopped while sertraline treatment continued for 4 weeks.

Results: Depression scores decreased substantially in both groups, resulting in high response and remission rates in both groups after 9 weeks of treatment. The difference in depression scores at week 5, favouring the bright-light-treated group, disappeared gradually in the 4-week follow-up period, resulting in similar end-point scores.

Conclusions: Bright light did not have a sustained effect after discontinuation. The offset of effect was complete after 4 weeks.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S0033291706008105DOI Listing

Publication Analysis

Top Keywords

bright light
12
follow-up period
12
non-seasonal major
8
major depression
8
bright-light therapy
8
light sustained
8
sustained discontinuation
8
4-week follow-up
8
sertraline combined
8
depression scores
8

Similar Publications

Nonlocal Huygens' meta-lens for high-quality-factor spin-multiplexing imaging.

Light Sci Appl

January 2025

Department of Electrical Engineering, City University of Hong Kong, Kowloon, Hong Kong SAR, China.

Combining bright-field and edge-enhanced imaging affords an effective avenue for extracting complex morphological information from objects, which is particularly beneficial for biological imaging. Multiplexing meta-lenses present promising candidates for achieving this functionality. However, current multiplexing meta-lenses lack spectral modulation, and crosstalk between different wavelengths hampers the imaging quality, especially for biological samples requiring precise wavelength specificity.

View Article and Find Full Text PDF

The T22 protocol is an animal model of forced internal desynchronization, in which rats are exposed to an 11:11 light-dark (LD) cycle. This non-invasive protocol induces the dissociation of circadian rhythms in adult rats, making it possible to study the effects of circadian disruption on physiological and behavioral processes such as learning, memory, and emotional responses. However, the effects of circadian dissociation during other developmental stages, such as adolescence, remain unexplored.

View Article and Find Full Text PDF

Rationally manipulating molecular planarity to improve molar absorptivity, NIR-II brightness, and photothermal effect for tumor phototheranostics.

Biomaterials

January 2025

Lab of Molecular Imaging and Translational Medicine (MITM), Engineering Research Center of Molecular and Neuro Imaging, Ministry of Education, School of Life Science and Technology, Xidian University & International Joint Research Center for Advanced Medical Imaging and Intelligent Diagnosis and Treatment, Xi'an, Shaanxi, 710126, China. Electronic address:

The secondary near-infrared region (NIR-II) fluorescence imaging-guided photothermal therapy (PTT) offers a noninvasive and light-controllable treatment option for deep-seated cancers. However, the development of NIR-II photothermal agents (NIR-II PTAs) that possess the desired properties of high molar absorption coefficient (ε), fluorescence quantum yield (QY), and photothermal conversion efficiency (PCE) remain a challenge due to the contradiction between radiative and nonradiative processes. Herein, we propose a novel side-chain heteroatom substitution engineering strategy to simultaneously enhance ε, QY, and PCE by modifying the molecular planarity.

View Article and Find Full Text PDF

Landau-Levich Scaling for Optimization of Quantum Dot Layer Morphology and Thickness in Quantum-Dot Light-Emitting Diodes.

ACS Nano

January 2025

Department of Chemical and Biomolecular Engineering, Lehigh University, 124 E. Morton Street, Bethlehem, Pennsylvania 18015, United States.

Quantum dot (QD) light-emitting diodes (QLEDs) are promising candidates for next-generation displays because of their high efficiency, brightness, broad color gamut, and solution-processability. Large-scale solution-processing of electroluminescent QLEDs poses significant challenges, particularly concerning the precise control of the active layer's thickness and uniformity. These obstacles directly impact charge transport, leading to current leakage and reduced overall efficiency.

View Article and Find Full Text PDF

Light pollution disrupts the natural dark-light rhythmicity of the world and alters the spectral composition of the nocturnal sky, with far-reaching impacts on natural systems. While the costs of light pollution are now documented across scales and taxa, community-level mitigations for arthropods remain unclear. To test two light pollution mitigation strategies, we replaced all 32 streetlights in the largest visitor center in Grand Teton National Park (Wyoming, USA) to allow wireless control over each luminaries' color and brightness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!