The authors describe two methods of suturing injured finger tendons and requirements to suture material. A polyamide monofilament thread with a conventional number 3/0 used by the authors for a removable suture of the tendon is the suture material of choice. For a buried suture it is expedient to use absorbable threads which begin degrading within three weeks after operation. The developed by the authors loop-shaped removable and buried sutures are strong, atraumatic and simple for fulfillment.

Download full-text PDF

Source

Publication Analysis

Top Keywords

suture material
12
[suture suture
4
material surgery
4
surgery finger
4
finger tendons]
4
tendons] authors
4
authors describe
4
describe methods
4
methods suturing
4
suturing injured
4

Similar Publications

Purpose: Small-bites suturing technique for laparotomy closure is now recommended as the standard of care. However, uptake of the practice remains slow. A medical technology called the SutureTOOL has been developed which can facilitate implementation of small-bites.

View Article and Find Full Text PDF

A 64-year-old woman suffered a traumatic rupture of the inferior rectus muscle, with the distal segment unrecoverable. An inferior oblique muscle transposition, augmented with a posterior fixation suture, was performed. This modification may have contributed to the surgical outcome.

View Article and Find Full Text PDF

Purpose: This study aims to compare the biomechanical performance of elastic and static suture-based cerclage systems to traditional screw constructs in the setting of modeled glenoid bony augmentation.

Methods: Biomechanical testing was conducted on polyurethane cellular foam blocks modeling a 20 % glenoid defect repaired with a coracoid graft. Constructs consisted of an elastic suture-based cerclage, static suture-based cerclage, and a two-screw construct.

View Article and Find Full Text PDF

Purpose: This study aimed to compare the biomechanical properties of four meniscal suture configurations-two simple sutures (TSS), two cinch sutures, a locking loop stitch (LLS), and a delta-grip stitch (DGS)-for transtibial pullout repair of medial meniscus posterior root tears (MMPRTs) using porcine menisci.

Methods: Forty porcine menisci were randomly assigned to each suture configuration with all-inside repair. All specimens were subjected to cyclic loading for 1000 cycles, followed by a load-to-failure test.

View Article and Find Full Text PDF

Background: Long-gap esophageal atresia (LGEA) can complicate the management of esophageal atresia (EA) with or without a tracheoesophageal fistula (TEF). This series describes a short interval, staged, thoracoscopic internal traction approach for LGEA with distal TEF to manage complex anastomotic tension or an anatomically impossible esophageal anastomosis.

Methods: A retrospective review (2018-2024) was performed across four tertiary centers to identify patients with LGEA and distal TEF, managed with a staged, thoracoscopic internal traction approach.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!