Late, clinically manifest, adverse inflammatory reactions have sometimes occurred after the use of slowly degrading bioabsorbable poly-l-lactide (PLLA) devices in clinical series of bone fixation. In this study, long-term tissue response to bioabsorbable fracture fixation screws made of poly-l-lactide and to similar metallic screws in cancellous bone was examined and compared with intact bone. The postoperative evaluation of the rabbit femora was performed by using plain radiography, microradiography, histology, histomorphometry, and oxytetracycline labeling studies. The follow-up times were 36 and 51 months in groups of 15 and 14 rabbits, respectively. A walling-off response by formation of trabecular bone which outlined the screw profile was observed in the PLLA and metallic groups both. Connective tissue between this bone front and the implant was seen only in the PLLA group. There was no difference in the thickness of the layer between the two follow-up groups. Between the surgically handled femora and the intact control bone, there was no statistically significant difference in the amount of trabecular bone. The osteoid formation activity in the tissue-implant interface showed no differences between the groups. However, active osteoblasts were visible only in the PLLA group. The amount of birefringent PLLA material diminished between the 36-month and the 51-month follow-up groups. Within the follow-up times of this study, both the PLLA screws and the metallic screws were rather inert. Also, long-term walling-off was a typical response to both PLLA and metallic screws in cancellous bone. PLLA screws did not evoke any osteostimulatory reaction over the long-term follow-up. The findings clearly demonstrated that the overall degradation process of PLLA was very slow and accompanied by fibrous tissue formation. Macrophage activity seemed to be related to the slow degradation process of PLLA and might be associated with the formation of connective tissue replacing the original implant. The results of this study showed no significant differences between the bioabsorbable PLLA screws and the metallic screws in biocompatibility, and no signs of inflammatory foreign-body reactions occurred during the follow-up.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bone.2006.04.009 | DOI Listing |
Medicina (Kaunas)
December 2024
Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.
: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Pediatric Orthopedics, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, Hunan, 410013, China.
Backgroud: Medial humeral epicondyle fracture is a prevalent type of upper limb fractures in pediatric patients. This study aims to compare the follow-up clinical results and complications in 30 children with medial epicondyle fractures who were treated with either metal screws or absorbable screws at our hospital.
Methods: A retrospective review was conducted on 30 children with medial humeral epicondyle fractures, who were divided into two groups: Metal group (18 children) underwent fixation using metal screws, while Absorbable group (12 children) received absorbable screws between January 2016 and June 2024.
BMC Oral Health
December 2024
Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand.
Background: The selection guideline for the implant-supported bar connectors (ISBC) of hybrid denture is lacking. This study investigated the maximum von Mises stress (vMS), stress distribution, and displacement of various geometric ISBC in mandibular hybrid dentures, as well as the maximum principal stress (σmax) in the acrylic resin part, through finite element analysis.
Methods: Four different geometric cross-sectional patterns for mandibular ISBC-L, Y, I, and Square-of equal volume, based on the "All-on-4" concept, were created.
Rev Bras Ortop (Sao Paulo)
November 2024
Ortopedia e Traumatologia, Hospital Universitário de Santa Maria, Santa Maria, RS, Brasil.
Osteochondral injuries in the knee are uncommon in the immature skeleton and are usually related to sporting activities. Fixation is required depending on the size and location of the fragment. The standard technique is open reduction and internal fixation with metal screws, which are removed in a second procedure after consolidation.
View Article and Find Full Text PDFPlast Aesthet Nurs (Phila)
December 2024
Sowmya Srinivas, BDS, MDS, PhD, is an Assistant Professor at the Department of Prosthodontics, JSS Dental College and Hospital, JSS Academy of Higher Education and Research, Mysore, Karnataka, India.
Placing an implant immediately into extraction sockets provides a distinct advantage over delayed placement, eliminating the need for a 4 to 6 months waiting period for bone formation. However, when patients present with hypothyroidism, the feasibility of immediate placement of dental implants becomes uncertain. This case involved a hypothyroid woman in her late 60s with loose lower anterior teeth.