Diabetic peripheral neuropathy (DPN) has been identified as a key element in the causal pathway to foot ulceration and other lower-extremity complications, impaired quality of life and increased mortality. Early detection is essential to optimise effective risk management, including adequate foot care, patient education, and future pharmacological therapy. However, data suggest that screening has been mostly sub-optimal, and many physicians remain unfamiliar with non-invasive screening tests. There is evidence in the literature to suggest that vibration perception threshold (VPT) measures can be used to easily and accurately identify at-risk diabetic patients, including those with early neuropathic deficits. These measures have been used in population-based studies and are associated with an increased risk of severe and expensive outcomes, such as ulcers and amputations. Incorporating VPT testing into clinical practice has the potential to significantly improve the outcomes in patients with DPN, thereby substantially reducing the socio-economic burden of this common and challenging disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/dmrr.657 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Communication Science and Disorders, University of Pittsburgh, Pittsburgh, PA 15213.
Nat Commun
January 2025
Robotics Institute and State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China.
Hydrogel-based soft machines are promising in diverse applications, such as biomedical electronics and soft robotics. However, current fabrication techniques generally struggle to construct multimaterial three-dimensional hydrogel architectures for soft machines and robots, owing to the inherent hydrogel softness from the low-density polymer network nature. Herein, we present a multimaterial cryogenic printing (MCP) technique that can fabricate sophisticated soft hydrogel machines with accurate yet complex architectures and robust multimaterial interfaces.
View Article and Find Full Text PDFBehav Res Methods
December 2024
Algoritmi Research Centre, University of Minho, Campus de Azurém, 4800-058, Guimarães, Portugal.
The vibration perception threshold (VPT) is the minimum amplitude required for conscious vibration perception. VPT assessments are essential in medical diagnostics, safety, and human-machine interaction technologies. However, factors like age, health conditions, and external variables affect VPTs.
View Article and Find Full Text PDFBiomimetics (Basel)
December 2024
School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China.
This study develops biomimetic strategies for slip prevention in prosthetic hand grasps. The biomimetic system is driven by a novel slip sensor, followed by slip perception and preventive control. Here, we show that biologically inspired sensorimotor pathways can be restored between the prosthetic hand and users.
View Article and Find Full Text PDFHeliyon
December 2024
Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, 121205, Moscow, Russia.
Mental imagery is a crucial cognitive process, yet its underlying neural mechanisms remain less understood compared to perception. Furthermore, within the realm of mental imagery, the somatosensory domain is particularly underexplored compared to other sensory modalities. This study aims to investigate the influence of tactile imagery (TI) on cortical somatosensory processing.