The diffusion properties of biological tissues are independent of magnetic field strength. Field strength, however, does affect the signal-to-noise ratio (SNR) and artifacts of diffusion-weighted (DW) images, which ultimately will influence the quantitative and spatial accuracy of diffusion tensor imaging (DTI). In this article, the effects of field strength on DTI are reviewed. The effects of parallel imaging also are discussed. A small study comparing DTI measurements both as a function of field strength (1.5 T and 3.0 T) and parallel imaging was performed. Overall, the SNR of the DW images roughly doubled going from 1.5 T to 3.0 T, and there was a relatively small decrease in SNR (15% to 30%) when parallel imaging was used. The increased SNR at 3.0 T resulted in smaller variances in the estimated mean diffusivities and fractional anisotropies. As expected, the amount of echo-planar image distortion roughly doubled going from 1.5 T to 3.0 T, but was reduced by 50% when using parallel imaging. In summary, DTI studies at 3.0 T using parallel imaging will provide significantly improved DTI measurements relative to studies at 1.5 T.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.nic.2006.02.006 | DOI Listing |
Front Aging Neurosci
January 2025
Department of Radiology, The Third Affiliated Hospital of Zunyi Medical University (The First People's Hospital of Zunyi), Zunyi, Guizhou, China.
Background And Purpose: Asymptomatic carotid stenosis (ACS) is an independent risk factor for ischemic stroke and vascular cognitive impairment, affecting cognitive function across multiple domains. This study aimed to explore differences in static and dynamic intrinsic functional connectivity and temporal dynamics between patients with ACS and those without carotid stenosis.
Methods: We recruited 30 patients with unilateral moderate-to-severe (stenosis ≥ 50%) ACS and 30 demographically-matched healthy controls.
JACC Clin Electrophysiol
January 2025
Cardioangiologisches Centrum Bethanien, Agaplesion Markus-Krankenhaus, Frankfurt am Main, Germany.
Background: The net benefit of oral anticoagulation in patients with end-stage renal disease on hemodialysis (HD) is uncertain. In recent years, left atrial appendage closure (LAAC) has emerged as an alternative to oral anticoagulation; however, there is scant evidence of LAAC in patients on HD.
Objectives: This study aimed to assess the feasibility and safety of LAAC in patients on HD.
Int J Clin Health Psychol
January 2025
Faculty of Psychology, Tianjin Normal University, Tianjin, 300387, China.
World J Radiol
January 2025
Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague 12808, Czech Republic.
Background: Whole-body magnetic resonance imaging (wbMRI) allows general assessment of systemic cancers including lymphomas without radiation burden.
Aim: To evaluate the diagnostic performance of wbMRI in the staging of diffuse large B-cell lymphoma (DLBCL), determine the value of individual MRI sequences, and assess patients' concerns with wbMRI.
Methods: In this single-center prospective study, adult patients newly diagnosed with systemic DLBCL underwent wbMRI on a 3T scanner [diffusion weighted images with background suppression (DWIBS), T2, short tau inversion recovery (STIR), contrast-enhanced T1] and fluorodeoxyglucose (F-FDG) positron emission tomography/computed tomography (PET/CT) (reference standard).
Spatial differentiation is the key element for edge detection and holds unquestionable significance in the current information era. All-optical computation based on metasurfaces has emerged as a powerful platform for spatial differentiation due to its advantage of high integration and parallel processing. However, while most current works focus on one- or two-dimensional (2D) spatial differentiation, three-dimensional (3D) all-optical computation for compact spatial differentiator remains elusive.