A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cobalt tetrasulphonated phthalocyanine immobilized on poly-L-lysine film onto glassy carbon electrode as amperometric sensor for cysteine. | LitMetric

The present work describes the development of a simple and efficient method for the amperometric determination of cysteine (CySH) in wild medium at an applied potential of 0.150 V versus Ag/AgCl. In this sense, the electrocatalytic oxidation of cysteine (CySH) was carried out on a glassy carbon electrode modified with cobalt tetrasulphonated phthalocyanine (CoTSPc) and poly-L-lysine (PLL) film. The immobilization of CoTSPc in PLL film was performed by a simple evaporation of the solvent. The CoTSPc/PLL film, formed on the GC electrode showed an electrocatalytic activity to the CySH oxidation. The sensor presented its best performance in 0.1 mol l(-1) Pipes at pH 7.5. Under optimized operational conditions, the sensor provided a wide linear response range for CySH from 0.50 up to 216.0 micromol l(-1) with a sensitivity and detection limit of 157 nA cm(-2) l micromol(-1) and 150 nmol l(-1), respectively. The proposed sensor presented higher sensitivity when compared to the other modified electrodes described in the literature and showed a stable response for at least 200 successive determinations. The repeatability of the measurements with the same sensor and different sensors, evaluated in term of relative standard deviation, were 4.1 and 5.2%, respectively, for n=10. The developed sensor was applied for the CySH determination in food supplement samples and the results were statistically the same to those obtained by a comparative method described in the literature at a confidence level of 95%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2006.03.036DOI Listing

Publication Analysis

Top Keywords

cobalt tetrasulphonated
8
tetrasulphonated phthalocyanine
8
glassy carbon
8
carbon electrode
8
cysteine cysh
8
pll film
8
sensor presented
8
described literature
8
sensor
6
cysh
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!