A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Can LigaSure seal and divide the small bowel? | LitMetric

Can LigaSure seal and divide the small bowel?

Am J Surg

Department of Surgery, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216, USA.

Published: June 2006

Background: The LigaSure system (Valleylab, Boulder, CO) seals vessels by reforming collagen and elastin in vessel walls. We studied the feasibility and effectiveness of LigaSure in dividing porcine small bowel.

Methods: Twelve porcine small bowel portions were randomized to division with either endoscopic linear stapler or LigaSure system and the burst pressure of the sealed ends were measured.

Results: Segments sealed with staples (6), LigaSure Atlas (Valleylab) (7), LigaSure Xtd (Valleylab) (4), and double-sealed with LigaSure Atlas (Valleylab) (4) were compared. Burst pressure for stapled segments was 131 (standard deviation [SD] 19) mm Hg; failure occurred in the bowel wall. Burst pressures for the 3 groups of Ligasure segments were 27 (SD 5), 20 (SD 6), and 11 (SD 13) mm Hg, respectively, with no statistically significant difference among them; failure occurred at the sealed end. Burst pressure for stapled segments was significantly higher than that of Ligasure segments (P < .001).

Conclusion: LigaSure does not safely seal small bowel.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2005.05.045DOI Listing

Publication Analysis

Top Keywords

burst pressure
12
ligasure
10
ligasure system
8
porcine small
8
small bowel
8
ligasure atlas
8
atlas valleylab
8
pressure stapled
8
stapled segments
8
failure occurred
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!